31
5.MODULE INSTALLATION
Follow the below installation procedure for modules (or dummy modules).
When old modules (or dummy modules) are to be removed, follow the procedure in the MODULE
REMOVAL section.
The module is shipped as shown in 2.2. A separate order is required for parts shown in 2.3.
Precautions
Implement work protocols that avoid leaving the module exposed to air for extended periods
during assembly and installation. Be cognizant of the differences between the top and bottom of
the module. The module head marked "Feed" should be placed at the bottom and the head
marked "Reject" at the top.
Modules must not be subjected to sudden impact, mechanical shock, or vibration as it may
result in damaged membranes even if there is no damage to the housing.
5.1 Installing Module Parts
1. Unpack the module from the shipping carton and remove the plastic bag.
2. Remove the top and bottom End Caps and the cap nut of the upper retentate nozzle.
3. Raise the module upright to drain the preservative. * 100 - 500ml
4. If the solution comes in contact with eyes or skin, immediately rinse thoroughly with water.
Caution
The membrane is wetted with a 30% calcium chloride solution. Always wear
protectors, such as safety goggles and rubber gloves, to prevent skin contact and
eye contact.