background image

取扱説明書

 

User’s  Manual 

AVNVM                                                                                                                                                                                                                                                                                       

10

 

単位(Unit)  :  ㎜ 

 

その他の継手はご相談ください。

 

※  参考値です。

 

 

Consult us for other fitting.

 

  It is reference value. 

単位(Unit)  :  ㎜ 

単位(Unit)  :  ㎜ 

 

接続チューブサイズ 

※       

Connecting tube size

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

“接続方法・チューブ”  サイズ   

 

“Connection

tube”

 

size

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

“接続方法・Rc、FNPT”  サイズ   

“Connection

Rc, FNPT”

 

size

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

06

10

12

Flowell 20 series
Flowell 60 series

Super Type Pillar fitting

Super 300 Type Pillar fitting

Flowell 20 series
Flowell 60 series

Flare Type

Super Type Pillar fitting

Super 300 Type Pillar fitting

inch

6.35×4.35

9.53×6.35

12.70×9.53

6.35×3.95

9.53×6.33

12.7×9.5

チューブ径 Tube diameter

mm

6×4

10×8

12×10

06

10

12

mm

6×4

10×8

12×10

inch

6.35×4.35

9.53×6.35

12.70×9.53

Outer diameter tolerance

Thickness tolerance

Tube length

30

30

30

チューブ径 Tube diameter

±0.1

06

10

12

φD

Rc 1/4″

Rc 3/8″

Rc 1/2″

L

11

13

16

φD

FNPT 1/4″ FNPT 3/8″ FNPT 1/2″

L

11

13

16

Rc

FNPT

チューブ径 Tube diameter

Содержание Dymatrix AVNVM

Страница 1: ...o DTS111 07 1 General cautions 5 Part names 6 Specifications 7 How to select types 9 Dimension 11 How to operate 12 Technical data 13 Method of installation 14 Method of piping 16 Check items 17 Cause...

Страница 2: ...User s Manual AVNVM 1 General cautions 1 2 AV V 029 EJ N2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2...

Страница 3: ...User s Manual AVNVM 2 1 1 AV V 029 EJ N2 2 3 4 5 6 1 2 3 4...

Страница 4: ...lve unable to seal 4 Please contact us when use for the fluid containing the crystalline substance It would make the valve unable to seal 5 Use the products within the range of working pressure shown...

Страница 5: ...ding on the working condition If cavitations are observed review the fluid pressure and piping design 3 Do not use the valve in negative pressure It can be damaged 4 Handle the products carefully to p...

Страница 6: ...User s Manual AVNVM 5 Parts names Body Diaphragm Actuator O O ring Metal parts Parts Chemical resistant Wetted parts 0 1 PFA PTFE SUS304 SUS304 PTFEcoating PTFE PVDF FKM EPDM Viflon F Kalrez 6190...

Страница 7: ...0 25 Items Unit 35 Ambient Temperature 5 60 Flowell 20 series Flowell 60 series Super Type Pillar Fitting Super 300 Type Pillar Fitting Flare Type Tube Rc Actuation Medium Temperature Proof Pressure W...

Страница 8: ...x 9 53 M I S Ordering code example AVNVM30 010 PT3I1SV006 P P Body Materials 1 2 6 Actuator Size 1 30 35 35 30 AVNVM S Connection 1 PFA PTFE 06 10 12 6 x 4 10 x 8 12 x 10 mL min mL min mL min L min Co...

Страница 9: ...9L min 10L min 0 500 1000 1500 2000 2500 3000 3500 4000 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Flow rate mL min Handle rotations 3800mL min 3000mL min 1800mL min 0 200 400 600 800 1000 1200 1400 0...

Страница 10: ...109 Super Type Pillar Fitting inch mm 69 88 95 Super 300 Type Pillar Fitting inch mm 68 85 93 Flare Type inch 86 97 101 Tube inch mm 90 95 95 30 Max 104 5 21 5 5 6 4 10 8 12 10 6 35 4 35 9 53 6 35 12...

Страница 11: ...itting Flowell 20 series Flowell 60 series Flare Type Super Type Pillar fitting Super 300 Type Pillar fitting inch 6 35 4 35 9 53 6 35 12 70 9 53 6 35 3 95 9 53 6 33 12 7 9 5 Tube diameter mm 6 4 10 8...

Страница 12: ...l the desired flow rate is achieved Handle More flow Less flow Unlock state Lock state 0 6N m Be sure to operate the handle with hands Please operate a handle within 0 6N m torque Clamping them with a...

Страница 13: ...User s Manual AVNVM 12 Fluid Water ambient The data shown here is the experimental values and the reference values Technical date Handle rotations Flow rate...

Страница 14: ...ee Dimension Flow direction The flow direction of this product is specified For the details see the separately attached specifications Always flow medium in a specified direction If omitted that may d...

Страница 15: ...User s Manual AVNVM 14 Method of piping Flowell 20 series 1 2 Flowell 60 series Super Type Pillar Fitting Super 300 Type Pillar Fitting Flare Type...

Страница 16: ...e inner surface of the tube Insert the tube provided with the ring into the main body by hand Turn nut up to the required clearance by spanner after tightening by hand firmly To check the tightness of...

Страница 17: ...nge We recommends you to check them at least once a year When finding any problem or trouble call us Check points Check items Valve Appearance flaw crack distortion discoloration Leakage from the valv...

Страница 18: ...by actuating The piston or spring is damaged Replace the valve Leakage in the fully closed position The diaphragm is abraded Replace the valve Flaw in the diaphragm or body Foreign matter is caught in...

Страница 19: ...of product improvement 2020 12 v07 110 0005 3 24 6 21 TEL 03 5826 8832 FAX 03 3834 7592 For inquiries contact Head Office Overseas Department Tel 81 3 5826 8831 Fax 81 3 3834 7592 21st Floor Ueno Fro...

Отзывы: