ELECTRIC WIRE LIFT
17
Mast holding belt
Overload Protection Device
The overload protection devise works to prevent over
loading.
The devise works when the load is over
approximately 150kg.
Once the devise is worked, it rumbles. And the lifting
movement is stopped. To restart, make the load
lighter than the maximum load capacity.
① Make the mast down to the minimum height and unplug
the unit.
② Loosen the fixing screw under the aluminum plate and
remove the aluminum plate from the mast.
③ Hold the slide button and put the slide legs into legs.
④ Loosen the leg fix ring on the slide ring and fold the
legs.
⑤ Tighten the leg fix ring on the slide ring again.
⑥ Set the mast holding belt onto the mast edge.
At the operation to lower the mast, if the mast goes
up after it is fully downed to the end. It means the
wire is not at the correct position and the winding
protection device does not work properly. Set the
wire at its correct position.
Shorten the mast to the minimum height to loose the
wire and unplug the unit. Set Winding Protection
Lever at the position of the right picture. (Wire
comes to the mast side.)
Then operate for downward and if the unit rumbles,
the wire is at the correct position and the winding
protection device works properly.
Overload Protection Device
Folding
Position of the Wire
Correct Wire Position
Wire
Winding Protection Lever
◆ Do not carry the unit at the mast holding belt.
CAUTION