ELECTRIC WIRE LIFT
15
Emergency Stop Button
Emergency Stop Button
Pull up
Pushed
For the emergency case, push the emergency stop
button.
The unit will stop immediately regardless of operation
for lift up or down.
The aluminum plate is kept to the same position
when the unit is stopped.
Pull up the emergency stop button.
In case emergency stop button cannot be pulled up,
① Unplug the unit.
② Mount the manual handle on and turn it left or right.
③ Pull up the emergency stop button with the
opposite hand.
④ The emergency stop button can be pulled up.
⑤ In case of cannot pull up the emergency stop button
even with ② - ④ procedure, remove the manual
handle from the unit and store at its fixing hook.
⑥ Plug the unit.
⑦ Set switch select the lever of the remote controller
at “UP” or “DOWN” and turn on just a moment.
⑧ Confirm that the motor is stopped completely and
pull the Emergency Stop Button.
Emergency Stop
Release from Emergency stop condition.
◆ The manual operation must be done with the unit unplugged.
◆ Do not operate the unit by motor during manual operation.
◆ Do not operate the unit using the remote controller with the manual
handle at the manual shaft. The manual handle rotate at high speed
and may hit the operator or the handle may fly and hit people
nearby resulting in injury or hit object nearby resulting in damage.
WARNING