11
ECOcycle Aurora Ⅱ
① [OPEN] high pressure side valve of manifold.
② [OPEN] suction valve.
[PURGE] Switching valve.
[OPEN] discharge valve.
③ [Disconnect] the hose which is connected to the liquid port of the cylinder.
* Hold the hose tightly.
④ [OPEN] the ball valve of the hose.
⑤ Set the Auto OFF/Manual switch to the [Manual] position.
⑥ Set the Power switch to the [ON] position.
⑦ When the suction pressure reaches vacuum, set the valve of the recovery machine to the [Purge]
position.
⑧ [Connect] hose(③)to liquid side of cylinder after the suction pressure gauge was reach vacuum
again.
⑨ Set the Power switch to the [OFF] position.
2)Evacuation of the recovery machine and the hoses
CLOSE
Liquid valve
OPEN
TAKE OFF
CONNECTION
8
3
CLOSE
Vapor valve
Tightly grip
System
Manifold
(Optional Acc)
Eco Cycle Aurora
Cylinder with over
protection sensor
CLOSE
Low pressure side
CLOSE
High pressure side
OPEN
Ball valve
CONTINUOUS
OPERATION
5
ON
6
OFF
9
PURGE
7
OPEN
Suction valve
PURGE
Switching valve
OPEN
Discharge valve
1
2
2
2
4
OPEN
Ball valve
4
CLOSE
Low
pressure side
High
pressure side
CLOSE
Hose
HOW TO USE