10
ECOcycle Aurora Ⅱ
① Connect the hoses as above.
② Connect the safety cable to the connector on the cylinder or on Limit Scale.
③ Install a fi lter to the suction port of the recovery machine.(Code No.TF011)
④ Install Molecular sieve pack drier(refer to page 20)after take off a back lid on the machine.
⑤ Connect a charge faster when recovering R134a and R12.
Recovery / Reclaim Operation
1)Connection of hose and cords
CLOSE
Liquid
valve
CLOSE
CLOSE
Low
pressure side
High
pressure side
CLOSE
Vapor
valve
System
Manifold
(Optional Acc)
Eco Cycle Aurora
Cylinder with over
protection sensor
Low pressure side
High pressure side
High pressure side
Liquid port
Safety cable
Filter
CLOSE
CLOSE
CLOSE
HOW TO USE
◆ Use our Limit Scale (Code No. LS452) when a cylinder without fl oat sensor is used.
◆ This replace operation doing as soon as possible to avoid spoiling the quality of fi lter drier.
CAUTION
CAUTION
◆ The recovery machine will not start without connecting the safety cable.
CAUTION
◆ Make sure the installing direction.
◆ Connect the fi lter dryer with holding the inlet valve
by wrench.
◆ Replace the fi lter every recovery of 90kg or when it is clogged.
CAUTION