For manual Die-Head
[Removal]
(1)
Loosen The Die-Nut
,
lower the link fully
,
tighten the Die-Nut and throw the Open-Close Lever
up to remove the Dies.(fig20)
(2)
When the Die-Head is lowered, pull out Dies Nos. 1 and 4 from above.
(3)
Lift and remove the Die-Head and pull Dies Nos. 2 and 3 downward.
[Installation]
(1)
Loosen The Die-Nut
,
lower the link fully
,
tighten the Die-Nut and throw the Open-Close Lever
up to remove the Dies.(fig.20)
(2)
Insert the Dies with the same number as that of each Die-Head until click sound is heard.
(3)
Make sure the numbers of Die-Head and Dies show on the same side.
20
・
Wear gloves to avoid cutting hands by the Dies.
・
Proper threading cannot be achieved unless the number on the Die-Head slot
matches that of the Dies.
Die-Nut
Open-Close Lever
Link
Loosen
Tighten
Lower
Cause up
〈
20
〉