Brackets can also be rotated 180 degrees from the conventional installation position.
If you are installing the power adaptor shelf on the switch, use the mid-chassis mounting holes on
both sides of the switch to provide better switch support. (See the installation instructions
provided with the power adaptor shelf.)
2.
Hold the switch with attached brackets up to the rack and move it vertically until rack holes line up with the
bracket holes, then insert and tighten the four number 12-24 screws holding the brackets to the rack.
Figure 12: Mounting the Aruba 2930F 8G PoE+ 2SFP+ Switch in a two-post rack
Horizontal surface mount option
Place the switch on a table or other horizontal surface. The switch comes with rubber feet in the accessory kit that
provide the required thermal transfer space (8.5 mm) under the switch.
Attaching the four rubber feet to the bottom of the switch is required to provide the necessary thermal
transfer space between the switch bottom and the horizontal surface.
Attach the rubber feet to the four corners on the bottom of the switch within the embossed angled lines. Use a
sturdy surface in an uncluttered area. You may want to secure the networking cables and switch power cord to the
table leg or other part of the surface structure to help prevent tripping over the cords.
Chapter 2 Installing the switch