artisan
™
34
MICRO-PROCESSOR
TEMPERATURE CONTROL
CONTROLLER INSTRUCTIONS FOR, UNDERBENCH CHILLERS, BOTTOM MOUNT CHILLERS
& CAKE FRIDGES
RS-411E
1. CAUTIONS
:
1.1 Before wiring, please make sure that power is switched off to prevent from getting electric shock.
1.2 The product should be avoided to install at humid environment.
1.3 To prevent the controller burning out, please make sure the water-proofed procedure is undertaken
during installation.
1.4 Please install according to the wiring diagram, in order to avoid incorrect wiring.
1.5 Before supplying the power, please always check if the wiring and input power is connected
correctly.
1.6 Please always read this instruction carefully before installation. If the damage is caused of
incorrectly wiring, the product would not be guaranteed.
2. SPECIFICATION
:
2.1 Dimension:
2.1.1 Front panel size:36.2mm (H) x 84.2mm (L) ± 1mm
2.1.2 Mounting size:33mm (H) x 72mm (W) x 85mm (D) ± 1mm
2.2 Operating temperature: -5°C ~ 55°C, < 90% RH (non–condensing)
2.3 Storage environment: -10°C ~ 65°C, < 90% RH (non–condensing)
2.4 Power voltage: AC100/240V ± 10%, single phase 50 / 60Hz. (Depending on the transformer)
2.5 Power consumption: Max. 6 watts (Not include each output contacts)
2.6 Temperature display range:
2.6.1 -40°C ~ 70°C, within ± 19°C: resolution 0.5°C, others: 1°C, tolerance ± 1.0°C
2.6.2 -40°F ~ 158°F, resolution 1°F, tolerance ± 2°F
2.7 Input/Output:
2.7.1 Compressor output contact capacity : 1.5HP / 250Vac
3/4HP / 125Vac
10A / 250Vac. / 125Vac Resistive load
2.7.2 Fan contact capacity : 1/4HP / 250Vac / 125Vac
5A / 250Vac / 125Vac resistive load
2.7.3 Indoor sensor: NTC, length 1.5m (If you need other length of sensor, please purchase
additionally)
2.7.4 Condenser sensor: NTC, length 1.5m
2.7.5 Compressor pressure alarm contact (PA)
2.7.6 External connect monitor: length 3m
3. FUNCTION
:
3.1 Button operation:
3.1.1 In normal condition (Except
E1.E2.E3.EE.IA,PA
), press
[SET]
button for 3 seconds to enter
setup mode, the monitor will show
“tS”
3.1.2 When the required parameter is shown, press
[
▲
]
or
[
▼
]
to choose parameter code
the order is as follows:
“tS”, “td”,
“dF”, “dt”, “AU”, “AL”, “HS”, “LS”, “Ad”, “AC”, “Cr”,
“CS” , “Ot” “dS”, “Ft”, “dr”, “dO”, “FC”, “dL”, “Ut”, “PS”, “OU”.
3.1.3 After choosing the required parameter code, press
[SET]
to enter parameter value and press
[
▲
]
or
[
▼
]
to adjust values.
3.1.4 If you want to set
“PS”
as the fifth parameter, the operation is as below:
3.1.4.1 In the normal condition, press
[SET]
for 3 seconds to enter setup mode
“tS”
3.1.4.2 Press
[
▲
]
or
[
▼
]
and after choosing
“PS”
code - press
[SET]
code to show the
set the parameter.
3.1.4.3 Press
[
▲
]
or
[
▼
]
to choose the fifth parameter code.
3.1.4.4 Press
[SET]
or wait for 15 seconds to memory, After showing
“rS”
, the controller will
restart and show the parameter group.
3.1.5 After amending the parameter, press
[SET]
to return to the showing of parameter code and
memory the am endment of parameter value.
3.1.6 If no more command is given within 15 seconds or after choosing
“OU”
, it will save the
amended parameter automatically and return to the showing of indoor temperature.
3.1.7 After changing the unit selection
“Ut”
, the controller will reset automatically and turn back to
default setting.
3.1.8 Rapid set point mode:
3.1.8.1 In the normal condition (except
E1.E2.E3.EE.IA.PA
), press
[
▼
]
button for 3 seconds
to enter the quick temperature setting mode, meanwhile, the value of setting
temperature flickers.
3.1.8.2 In this condition can press
[
▲
]
or
[
▼
]
button to adjust the temperature value
“tS”
directly.
Содержание LCF-411-RS
Страница 1: ......
Страница 3: ...artisan 2 ...
Страница 8: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 7 ...
Страница 22: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 21 ...
Страница 26: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 25 ...
Страница 30: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 29 ...
Страница 41: ...artisan 40 Room Sensor black wire need to connect to PIN 1 for ground purpose WIRING DIAGRAM ...
Страница 42: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 41 ...
Страница 50: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 49 ...
Страница 54: ......