1. CAUTION
:
1.1 Before wiring, please make sure that power is switched off to prevent from getting electric shock.
1.2 The product should be avoided to install at humid environment.
1.3 To prevent the controller burning out, please make sure the water-proofed procedure is undertaken
during installation.
1.4 Please install according to the wiring diagram, in order to avoid incorrect wiring,
1.5 Before supplying the power, please always check if the wiring and input power is connected
correctly.
1.6 Please always read this instruction carefully before installation. If the damage is caused of
incorrectly wiring, the product would not be guaranteed.
2. SPECIFICATION
:
2.1 Dimension:
2.1.1 Front panel size: 40mm (H) x 160mm (W) ± 1mm
2.1.2 Mounting hole size: 31.5mm (H) x 138mm (W) ± 1mm
2.2 Operating environment: -5°C~55°C, RH 20%~95% (non–condensing)
Storage environment: -10°C~55°C, RH 20%~95% (non–condensing)
2.3 Output/Input:
2.3.1 Power supply: AC 220V ± 10%, single phase 50 / 60Hz
2.3.2 Voltage alarm: Low voltage alarm=182VAC ± 10V, High voltage alarm=255VAC ± 10V.
2.3.3 Power consumption: Max. 10 Watts (controller only)
2.3.4 Temperature display range: -45°C~99°C, accuracy ± 1°C
2.3.5 Indoor temperature sensor: NTC, 1.5M (L)
2.3.6 Compressor contact capacity: 1.5HP/240VAC
2.3.7 Fan contact capacity: 2A / 220VAC
2.3.8 Capacity of Light switch: 2A / 220VAC Resistive load. (Be careful with surge current when
using LED lamps) (Use 187 type and 250 type connector, only for RS-617SE)
2.3.9 Defog contact capacity: 2A / 250VAC Resistance (Use 187 type and 250 type connector)
2.3.10 Alarm output: Built-in buzzer.
2.3.11 Indicator: Compressor Fan Defrost Power
2.3.12 Switch: Defog switch, Light switch
3. FUNCTION
:
3.1 Power ON/OFF: Press and hold it for 3 seconds to ON/OFF the power.
When the POWER turns OFF, the defog will be turned OFF.
3.2 Defrost: press and and hold them for 5 seconds to enter defrost mode or stop defrost
mode. (The operation cycle not be affected).
3.3 Parameters locked: In normal operation mode, press and and hold for 3 seconds to lock the
parameters, as “00” is displayed or to unlock “33” is displayed. The parameter cannot be
changed once locked, except temp, setting.
3.4 Buzzer:
3.4.1 Alarm mute SA=0: When the controller fails, buzzer will beep and display error code.
Beep could be turned off by pressing for 3 seconds.
3.4.2 Alarm mute SA=1: When the controller fails, buzzer will NOT beep and only display error code.
3.5 Restore default setting: Cut the power supply; press and hold and , then re-supply the
power. it will display rS, all of the parameter will be restored to default and operated accordingly.
3.6 Quick setting mode: Under the normal status, press and hold the key for 1 second to enter the
quick setting mode. Press or key to directly adjust the temp. setting value. If no key is
pressed within 5 seconds or directly press the key, the parameters will be saved automatically
and return to the temperature display.
3.7 Compressor forced start function: Under the normal status, press and hold and for 3
seconds, the compressor would be forced to start.
3.8 User’s parameter setup:
3.8.1 Press and hold for 3 seconds to enter the parameter set-up mode. The code “tS”
displayed, the indicator flashes.
3.8.2 When the parameter code is displayed, press or to select the parameter code.
Press to display the parameter value after selection. (please refer to 10. Parameter table
for parameter codes and setting range)
3.8.3 When the parameter value is displayed, press or to adjust parameter values. After the
setting is complete, press to confirm and return to the parameter code, or if no key
is pressed within 10 seconds, parameter values would be auto-saved and system returns to
normal status.
3.8.4 Under the parameter locked, the settings cannot be modified, except for tS
(Temperature setting).
RS-617SE; RS-617SAE Operation Manual
5INS00689
Содержание LCF-411-RS
Страница 1: ......
Страница 3: ...artisan 2 ...
Страница 8: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 7 ...
Страница 22: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 21 ...
Страница 26: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 25 ...
Страница 30: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 29 ...
Страница 41: ...artisan 40 Room Sensor black wire need to connect to PIN 1 for ground purpose WIRING DIAGRAM ...
Страница 42: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 41 ...
Страница 50: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 49 ...
Страница 54: ......