Problem:
Water in cabinet or on floor
Possible
Check condensate hose is securely in black
causes:
condensate tray at bottom rear; heater wires
on frame or door not on; blockage in evaporator tray.
Solution:
Secure condensate hose, check
evaporator tray for any blockage
(for example ice, insects etc.) and if dripping off doors
or door frames turn heater wires on. Also cabinet may
be running too cold and therefore producing too
much condensate. To fix this reduce differential and
up temperature.
Problem:
Stale smell or odour in cabinet
Possible
cause:
Food or liquid spill; uncovered food.
Solutions:
Clean inside of cabinet with a mild detergent and
warm water. Cover all food.
Problem:
Alarm sounding and digital screen reading CLn
Possible
cause:
This is a reminder to clean the condenser.
Solutions:
1)
Clean the filter and/or condenser coil
2)
Press the
▼
button for 5 seconds
3)
Turn off power to the cabinet at the power point,
and then back on again to re-set operation.
Problem:
Cabinet noisy
Possible
Causes:
Loose or rattling condenser cover; loose fan blade
Action:
Tighten all screws, check cabinet is level.
Содержание LCF-411-RS
Страница 1: ......
Страница 3: ...artisan 2 ...
Страница 8: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 7 ...
Страница 22: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 21 ...
Страница 26: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 25 ...
Страница 30: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 29 ...
Страница 41: ...artisan 40 Room Sensor black wire need to connect to PIN 1 for ground purpose WIRING DIAGRAM ...
Страница 42: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 41 ...
Страница 50: ...GENERAL OPERATING WARRANTY MANUAL FOR CHILLER FREEZER AND HEATED DISPLAY CABINETS 49 ...
Страница 54: ......