![Artesyn Centellis 2100 Shelf Release 3.0 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/artesyn/centellis-2100-shelf-release-3-0/centellis-2100-shelf-release-3-0_installation-and-use-manual_2977725057.webp)
Introduction
Centellis 2100 Shelf Release 3.0 Installation and Use (6806800T37D)
57
The shelf management system consists of several major components:
Distributed intelligent platform management controllers (IPMCs) which manage and
monitor the operation and environment conditions of each field replaceable unit (FRU) in
the shelf
Shelf manager which implements a system management interface and contains shelf
management controller (ShMC) through which it communicates with other IPMCs
Intelligent platform management interface (IPMI) infrastructure which provides
communication, management, and control paths among the distributed controllers and
to the shelf manager. The IPMI infrastructure is fully compliant to the
IPMI V.1.5
and
AdvancedTCA Specification
.
The shelf manager is the active instance of the software running on the ATCA-MF106 board.
For a detailed description refer to the
ATCA-MF106 Installation and Use
guide. For a description
of the HPI-B software refer to the
System Management Interface Based on HPI-B (Centellis CO
31kX/4100/2000) User’s Guide
.
Due to high availability software, utilizing redundant hardware components, system high
availability is ensured. Shelf management software runs on two redundant ATCA-MF106
boards.
The shelf manager performs the following main tasks:
Retrieving FRU inventory information
Receiving events from sensors of the shelf
Monitoring and controlling the temperature of the shelf
Reporting of errors
Executing corrective actions
Managing blades for hot swap functionality
1.4
System Management
The system manager function is provided by the end user and is responsible for managing one
or more Centellis 2100 shelves. The shelf manager of the ATCA-MF106 board provides an
interface (Hardware Platform Interface, HPI) to monitor and control the assigned shelves.
Содержание Centellis 2100 Shelf Release 3.0
Страница 1: ...Centellis 2100 Shelf Release 3 0 Installation and Use P N 6806800T37D August 2017...
Страница 8: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Contents 8 Contents Contents...
Страница 10: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 10 List of Tables...
Страница 12: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 12 List of Figures...
Страница 18: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D About this Manual 18 About this Manual...
Страница 32: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Safety Notes 32...
Страница 46: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Sicherheitshinweise 46...
Страница 66: ...Introduction Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 66...
Страница 112: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 112...
Страница 124: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 124...
Страница 130: ...Non Field Replaceable Units Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 130...
Страница 132: ...Cooling Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 132...
Страница 140: ...Power Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 140...
Страница 160: ...Network Management and System Access Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 160...
Страница 168: ...Configuration and Network Boot Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 168...
Страница 174: ...Redundancy Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 174...
Страница 186: ...Troubleshooting Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 186...
Страница 188: ...Related Documentation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 188...
Страница 189: ......