Troubleshooting
A.1
Error List
A typical AdvancedTCA system is highly sophisticated. This chapter can be taken as an error list
for detecting erroneous system configurations and strange behaviors. It cannot replace a
serious and sophisticated pre- and post-sales support during application development.
If it is not possible to fix a problem with the help of this chapter, contact your local sales
representative or Field Application Engineer (FAE) for further support.
A.1.1
Mechanical
A.1.2
After Power On
Error
Possible Reason
Solution
Unable to insert board into
backplane
Closed handles
Open handles
Keying position
Check keying
Safety ground pin not aligned
Check safety ground pins
Damaged plugs, bent or broken
pins: backplane defective
Check whether backplane
connectors are in proper
condition
Error
Possible Reason
Solution
No response when the
system is powered on
No power at the power supply.
Verify that power is available at
the power supply.
Some component was jarred
loose during shipping.
Check that components are
seated properly and the thump-
wheel screws are tight.
Pins in a backplane connector are
bent or broken.
Contact Artesyn Technical
Support Services.
Содержание Centellis 2100 Shelf Release 3.0
Страница 1: ...Centellis 2100 Shelf Release 3 0 Installation and Use P N 6806800T37D August 2017...
Страница 8: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Contents 8 Contents Contents...
Страница 10: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 10 List of Tables...
Страница 12: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 12 List of Figures...
Страница 18: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D About this Manual 18 About this Manual...
Страница 32: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Safety Notes 32...
Страница 46: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Sicherheitshinweise 46...
Страница 66: ...Introduction Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 66...
Страница 112: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 112...
Страница 124: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 124...
Страница 130: ...Non Field Replaceable Units Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 130...
Страница 132: ...Cooling Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 132...
Страница 140: ...Power Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 140...
Страница 160: ...Network Management and System Access Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 160...
Страница 168: ...Configuration and Network Boot Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 168...
Страница 174: ...Redundancy Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 174...
Страница 186: ...Troubleshooting Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 186...
Страница 188: ...Related Documentation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 188...
Страница 189: ......