Hardware Preparation and Installation
ATCA-7475 Installation and Use (6806800S38D
)
48
The blade must be connected to a TNV-2 or a safety-extra-low-voltage (SELV) circuit. A TNV-2
circuit is a circuit whose normal operating voltages exceed the limits for a SELV circuit under
normal operating conditions, and which is not subject to over voltages from
telecommunication networks.
Table 2-3 Power Requirements
Characteristic
Value
Rated Voltage
Exception in the US and Canada
-48 VDC to -60 VDC
-48 VDC
Operating Voltage
Exception in the US and Canada
-39 VDC to -72 VDC
-39 VDC to -60 VDC
Max. power consumption of ATCA-7475 (with ATCA-
7470-ACCEL-MOD and with RTM-ATCA-736x-10G
including SAS HDD)
All product variants except ATCA-7475-
xGB-CE: 250W (typ. 215W)
ATCA-7475-xGB-CE variant: 300W (typ.
265W)
Max. power consumption of ATCA-7475 (without
ATCA-7470-ACCEL-MOD and without RTM)
All product variants except ATCA-7475-
xGB-CE: 210W (typ. 170W)
ATCA-7475-xGB-CE variant: 260W (typ.
220W)
Содержание ATCA-7475
Страница 1: ...ATCA 7475 Installation and Use P N 6806800S38D May 2014 ...
Страница 24: ...ATCA 7475 Installation and Use 6806800S38D About this Manual 24 About this Manual ...
Страница 34: ...ATCA 7475 Installation and Use 6806800S38D Sicherheitshinweise 34 ...
Страница 42: ...Introduction ATCA 7475 Installation and Use 6806800S38D 42 ...
Страница 64: ...Hardware Preparation and Installation ATCA 7475 Installation and Use 6806800S38D 64 ...
Страница 80: ...Controls Indicators and Connectors ATCA 7475 Installation and Use 6806800S38D 80 ...
Страница 138: ...Functional Description ATCA 7475 Installation and Use 6806800S38D 138 ...
Страница 250: ...Supported IPMI Commands ATCA 7475 Installation and Use 6806800S38D 250 ...
Страница 268: ...FRU Information and Sensor Data Records ATCA 7475 Installation and Use 6806800S38D 268 ...
Страница 276: ...Replacing the Battery ATCA 7475 Installation and Use 6806800S38D 276 Figure A 1 Location of On board Battery ...
Страница 281: ......