Supported IPMI Commands
ATCA-7475 Installation and Use (6806800S38D)
241
9.4.11 Set Payload Communication Time-Out Command
The Set Payload Communication Time-Out command sets the payload communication time-
out value.
5
Payload Time-out
Payload communication time-out measured in hundreds
of milliseconds. Thus, the payload communication time-
out may vary from 0.1 to 25.5 seconds.
Table 9-39 Get Payload Communication Time-Out Command Description (continued)
Type Byte
Data
Field
Table 9-40 Set Payload Communication Time-Out Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
Payload Time-out
Payload communication time-out measured in hundreds
of milliseconds. Thus, the payload communication time-
out may vary from 0.1 to 25.5 seconds.
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Содержание ATCA-7475
Страница 1: ...ATCA 7475 Installation and Use P N 6806800S38D May 2014 ...
Страница 24: ...ATCA 7475 Installation and Use 6806800S38D About this Manual 24 About this Manual ...
Страница 34: ...ATCA 7475 Installation and Use 6806800S38D Sicherheitshinweise 34 ...
Страница 42: ...Introduction ATCA 7475 Installation and Use 6806800S38D 42 ...
Страница 64: ...Hardware Preparation and Installation ATCA 7475 Installation and Use 6806800S38D 64 ...
Страница 80: ...Controls Indicators and Connectors ATCA 7475 Installation and Use 6806800S38D 80 ...
Страница 138: ...Functional Description ATCA 7475 Installation and Use 6806800S38D 138 ...
Страница 250: ...Supported IPMI Commands ATCA 7475 Installation and Use 6806800S38D 250 ...
Страница 268: ...FRU Information and Sensor Data Records ATCA 7475 Installation and Use 6806800S38D 268 ...
Страница 276: ...Replacing the Battery ATCA 7475 Installation and Use 6806800S38D 276 Figure A 1 Location of On board Battery ...
Страница 281: ......