![Artesyn ATCA-7475 Скачать руководство пользователя страница 165](http://html1.mh-extra.com/html/artesyn/atca-7475/atca-7475_installation-and-use-manual_2977729165.webp)
Maps and Registers
ATCA-7475 Installation and Use (6806800S38D)
165
6.4.11.3 Processor Hot Status Register
This register reflects the status of CPU temperature related signals. This is read only register.
6.4.11.4 Telecom Interrupt Control/Status Register
This register reflects the status of telecom related interrupt signals. Each of the Telecom
interrupt source can be enabled.
Table 6-31 Processor Hot Status Register
Address Offset: 0x21
Bit
Description
Default
Access
0
CPU0_PRCHT_ indicates if CPU0 is Hot
0: Normal temperature
1: CPU0 is overheated
Ext.
LPC: r
1
CPU1_PRCHT_ indicates if CPU1 is Hot
0: Normal temperature
1: CPU1 is overheated
Ext.
LPC: r
3:2
Reserved
Ext.
LPC: r/w
4
Reflects the status of the signal IPMC_THROTTLE_REQ
-
LPC: r
5
Reflects the status of the signal PCH0_THROTTLE_REQ
Ext
LPC: r
6
Reflects the status of the signal CPU0_VRHOT_
Ext
LPC: r
7
Reflects the status of the signal CPU1_VRHOT_
Ext
LPC: r
Table 6-32 Telecom Interrupt Control/Status Register
Address Offset: 0x22
Bit
Description
Default
Access
0
Telecom CLK_MONITOR_FINISHED interrupt Event 0:
One or more Telecom Clock measurements have
finished.
-
LPC: r
1
Telecom CLK_MONITOR_OUT_OF_RANGE interrupt
Event 1:
One or more Telecom Clocks are out of range.
-
LPC: r
Содержание ATCA-7475
Страница 1: ...ATCA 7475 Installation and Use P N 6806800S38D May 2014 ...
Страница 24: ...ATCA 7475 Installation and Use 6806800S38D About this Manual 24 About this Manual ...
Страница 34: ...ATCA 7475 Installation and Use 6806800S38D Sicherheitshinweise 34 ...
Страница 42: ...Introduction ATCA 7475 Installation and Use 6806800S38D 42 ...
Страница 64: ...Hardware Preparation and Installation ATCA 7475 Installation and Use 6806800S38D 64 ...
Страница 80: ...Controls Indicators and Connectors ATCA 7475 Installation and Use 6806800S38D 80 ...
Страница 138: ...Functional Description ATCA 7475 Installation and Use 6806800S38D 138 ...
Страница 250: ...Supported IPMI Commands ATCA 7475 Installation and Use 6806800S38D 250 ...
Страница 268: ...FRU Information and Sensor Data Records ATCA 7475 Installation and Use 6806800S38D 268 ...
Страница 276: ...Replacing the Battery ATCA 7475 Installation and Use 6806800S38D 276 Figure A 1 Location of On board Battery ...
Страница 281: ......