Supported IPMI Commands
ATCA-7475 Installation and Use (6806800S38D)
227
9.3.2.1
Set Feature Configuration
This command can be used to enable/disable features configurations within the IPMC during
runtime.
Table 9-25 Set Feature Configuration Command
Byte Data
Field
Request Data
1
LSB of Artesyn IANA Enterprise Number. A value of CDh shall be
used.
2
2nd byte of Artesyn IANA Enterprise Number. A value of 65h
shall be used.
3
MSB of Artesyn IANA Enterprise Number. A value of 00h shall
be used.
4
Feature Selector. For details, please see table 3
5
Feature Configuration.
00h = disabled (Feature Selector = E0)
01h = enabled (Feature Selector = E0)
02h – FFh = reserved
6
Persistency / Duration
00h = volatile. Actual duration depends on implementation.
01h – FFh = reserved
Response Data
1
Completion Code. Generic plus the following command-
specific completion codes:
80h = feature selector not supported.
81h = feature configuration not supported
83h = configuration persistency / duration not supported
2
LSB of Artesyn IANA Enterprise Number. A value of CDh shall be
used.
3
2nd byte of Artesyn IANA Enterprise Number. A value of 65h
shall be used.
4
MSB of Artesyn IANA Enterprise Number. A value of 00h shall
be used.
Содержание ATCA-7475
Страница 1: ...ATCA 7475 Installation and Use P N 6806800S38D May 2014 ...
Страница 24: ...ATCA 7475 Installation and Use 6806800S38D About this Manual 24 About this Manual ...
Страница 34: ...ATCA 7475 Installation and Use 6806800S38D Sicherheitshinweise 34 ...
Страница 42: ...Introduction ATCA 7475 Installation and Use 6806800S38D 42 ...
Страница 64: ...Hardware Preparation and Installation ATCA 7475 Installation and Use 6806800S38D 64 ...
Страница 80: ...Controls Indicators and Connectors ATCA 7475 Installation and Use 6806800S38D 80 ...
Страница 138: ...Functional Description ATCA 7475 Installation and Use 6806800S38D 138 ...
Страница 250: ...Supported IPMI Commands ATCA 7475 Installation and Use 6806800S38D 250 ...
Страница 268: ...FRU Information and Sensor Data Records ATCA 7475 Installation and Use 6806800S38D 268 ...
Страница 276: ...Replacing the Battery ATCA 7475 Installation and Use 6806800S38D 276 Figure A 1 Location of On board Battery ...
Страница 281: ......