![Artesyn Embedded Technology ATCA-7490 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/artesyn-embedded-technology/atca-7490/atca-7490_installation-and-use-manual_2977758031.webp)
Safety Notes
ATCA-7490 Installation and Use (6806800U11F)
31
System
Damage
WARNING: The intra-building port (s) of the equipment or subassembly is suitable for
connection to intra-building or unexposed wiring or cabling only. The intra-building port (s) of
the equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as intra-
building interfaces only (Type 2 or Type 4 ports as described in GR-1089) and require isolation
from the exposed OSP cabling. The addition of primary protectors is not sufficient protection
in order to connect these interfaces metallically to OSP wiring.
The intra-building port (s) of the equipment or subassembly must use shielded intra-building
cabling/wiring that is grounded at both ends.
Operation
Blade
Damage
Blade surface
High humidity and condensation on the blade surface causes short circuits.
Do not operate the blade outside the specified environmental limits. Make sure the blade is
completely dry and there is no moisture on any surface before applying power.
Blade Overheating and Blade Damage
Operating the blade without forced air cooling may lead to blade overheating and thus blade
damage.
When operating the blade, make sure that forced air cooling is available in the shelf.
When operating the blade in areas of electromagnetic radiation ensure that the blade is bolted
on the system and the system is shielded by enclosure.
Injuries or Short Circuits
Blade or power supply
In case the O-Ring diodes of the blade fail, the blade may trigger a short circuit between input
line A and input line B so that line A remains powered even if it is disconnected from the power
supply circuit (and vice versa).
To avoid damage or injuries, always check that there is no more voltage on the line that has
been disconnected before continuing your work.
Содержание ATCA-7490
Страница 1: ...ATCA 7490 Installation and Use P N 6806800U11F December 2018 ...
Страница 12: ...ATCA 7490 Installation and Use 6806800U11F Contents 12 Contents Contents ...
Страница 20: ...ATCA 7490 Installation and Use 6806800U11F 20 List of Tables ...
Страница 38: ...ATCA 7490 Installation and Use 6806800U11F Sicherheitshinweise 38 ...
Страница 44: ...Introduction ATCA 7490 Installation and Use 6806800U11F 44 ...
Страница 66: ...Hardware Preparation and Installation ATCA 7490 Installation and Use 6806800U11F 66 ...
Страница 88: ...Controls Indicators and Connectors ATCA 7490 Installation and Use 6806800U11F 88 ...
Страница 106: ...Functional Description ATCA 7490 Installation and Use 6806800U11F 106 ...
Страница 199: ...BIOS ATCA 7490 Installation and Use 6806800U11F 199 Add an ISCSI Attempt ...
Страница 226: ...BIOS ATCA 7490 Installation and Use 6806800U11F 226 Figure 6 25 Event Log Viewer ...
Страница 356: ...IPMI Feature Set ATCA 7490 Installation and Use 6806800U11F 356 ...
Страница 360: ...Replacing the Battery ATCA 7490 Installation and Use 6806800U11F 360 ...
Страница 371: ......