![Artesis AMT Toolkit Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/artesis/amt-toolkit/amt-toolkit_user-manual_2977657066.webp)
Appendices
64
Edit
Settings
Menu
Group
Submenu
items
Description
Type
Range
Default
Value
Improve
iterations
Number of iterations
used in
IMPROVE
Edit/
Display
1 - 20000
12000
Update
iterations
Number of iterations
used for
UPDATE
Edit/
Display
10 –
20000
1500
Flash save
rate
Number of iterations
after which the flash
will be automatically
updated with new
data. If the device is
operating in a noisy
environment, this
value should be set
to a low number to
ensure minimal loss
of data due to power
outages, and resets
etc.
Edit/
Display
1 – 1000
100