AMU Use
26
3.4.6.
Running RESUME and UPDATE
3.4.6.1.
Canceling running
All the operating modes LEARN, IMPROVE, MONITOR and UPDATE can be stopped and
started at any time without significant effect on monitoring performance, by pressing the
CLEAR button (and providing the correct password). Subsequent restart of AMU can be
achieved by selecting RESUME from the main menu, which will cause AMU to continue in its
incomplete mode at the point of interruption. Thus, if it is necessary to stop AMU for any
reason, it can be restarted without affecting any existing data.
3.4.7.
Advanced use
It is possible to customize the behavior of AMU by adjusting various settings. As usual a
valid password must be supplied before the Edit Settings menu can be entered.
The following table summarizes the settings that can be changed together with their
significance. It is recommended that the original values of each setting be recorded prior to
changing them. After changing certain settings it may be necessary to relearn the motor.
Menu Group
Setting
Usage
Harmonic
Values
Harmonic Calc
Switch on/off calculation of harmonic values. Note that
the calculation of harmonic values can significantly
lengthen the cycle time.
Signal Select
The channel number (1-6) of the channel to be used for
harmonic calculations.
Calibration
Calibration
The calibration constants for the sensors on each
channel.
Alarm
Thresholds
Voltage balance
%
Maximum permitted voltage imbalance
Current balance
%
Maximum permitted current imbalance
Voltage range %
Maximum voltage range (as ± percentage range around
nominal)
Max Current %
Maximum permitted current upper limit (as percentage
above nominal)
Low voltage %
Minimum acceptable level below which voltage is
considered to be zero for line and power fault alarms
(as percentage of nominal)
Low current %
Minimum acceptable level, below which current is
considered to be zero for motor not running alarm (as
percentage of nominal)
Содержание AMT Toolkit
Страница 2: ......
Страница 34: ...Equipment Faults Diagnosis and Reporting 32...
Страница 69: ...Appendices 67 7 6 Appendix 6 Flowcharts for AMU use 7 6 1 Running AMU Edit Settings and Check Motor...
Страница 70: ...Appendices 68 7 6 2 Running AMU Learn...
Страница 71: ...Appendices 69 7 6 3 Running AMU MONITOR IMPROVE UPDATE...
Страница 72: ...Appendices 70 7 6 4 Running AMU Alarm conditions...
Страница 73: ...Appendices 71...
Страница 74: ...Appendices 72...