![ARTE MENTOR hydro Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/arte/mentor-hydro-series/mentor-hydro-series_installation-and-user-manual_2977310013.webp)
INSTALLATION
&
USAGE
MANUAL
FIREPLACE
| MENTOR Hydro
9 |
Page
5.8.
Hot air abduction
The space extending around and over the device up to the deflector must
be ventilated continuously. For this reason you must allow cool air from a
lower spot, for example, the bottom and the outlet of the hot air from above
(Pic. 5.8.1).
With that way, it can be achieved:
Higher safety
Increase of the temperature inside the heating room, because of the air
flow around the device (heat conduction).
The hot air extract grille must be placed on top of the trunk approximately
20cm from the ceiling. The grille must always be installed, as its purpose is to
allow, the heat that builds up inside the trunk to be released in the room and
also to relieve the pressure created.
Finally, at the paneling of the fireplace, a visiting slot should be constructed in
order for the installer or the user to have access to the internal parts of the
door and be able to perform maintenance. For the determination of the L and
H dimensions, you should consult the drawing at
Chapter
11
. Dimensions &
technical specifications.
5.9.
Connection with the heating system
The fireplace
ARTE® MENTOR
can be installed to work individually or in collaboration with any another water heating
device to be used for central or floor heating.
To ensure the safety of the device you must install an overheating safety
(Pic. 5.9.1)
, in order to protect the system
against possible overheating. Also in case of floor heating, it is necessary to use a buffer tank
(Pic. 5.9.2)
and a thermal
mixing valve
(Pic. 5.9.3)
to ensure constant temperature of the water in the floor pipes. These parts are not included in
the device.
Pic. 5.9.1
Pic. 5.9.2
Pic. 5.9.3
In any case the installation must be made by a qualified technician and in accordance
local law and the regulations
of each country, including all regulations referring to national and European standards
.
The installation can be set into operation only after it has been tested by a qualified inspector. Prior to installing the
new fireplace please contact the appropriate local authorities.
Pic. 5.8.1
NEVER use the device if it is not connected to a water heating circuit, which is full of
water!
The installation is made by using 1’’ hoses
.