9.3.

 

Cleaning the fireplace and the flue 

When wood is burned slowly, it produces tar and other organic vapors, which combine with emitted moisture to form 
creosote. When the fire is low, the creosote vapors condense in the relatively cool chimney flue. As a result, creosote 
residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire, which can destroy the 
flue/chimney. 

Initially,  do  a  monthly  check  for  the  presence  of  soot  above  the  deflector  plate  and  around  the  outlet  flue.  If  the 
fireplace  suddenly  start  operating  slowly  check  for  intense  presence  of  soot  around  the  flue  collar  or  in  the 
flue/chimney.

 

Clean the flue/chimney all the way from the fireplace to the flue end point above the house.  A good practice is to 

clean  the  flue  after  each  operating  season  and  to  inspect  it  prior  to  the  start  to  ensure  that  bird’s  nests  or  other 

blockages have not occurred during the off season. 

Chimney sweeping 

Inspect the fireplace regularly during the operating season as part of a regular maintenance schedule.  

To  inspect  the  chimney,  let  the  fireplace  cool  completely.  Then,  remove  the  baffles 

(Pic.  9.4.1  &  9.4.2)

  and  the 

diaphragm of the central water tank pipe 

(Pic. 9.4.7)

, place a  mirror in the upper area of the combustion chamber 

and turn it upwards, in order to inspect the chimney. 

Clean  the  chimney  using  a  brush  with  the  same  size  and  shape  as  the  flue.  Run  the  brush  up  and  down  the  flue, 
causing  any  deposits  to  fall  to  the  bottom  of  the  fireplace  where  they  can  be  removed  the  same  way  as  the  ash. 

ΑΤΤΕΝΤΙΟΝ

!!!

  The  central  water  tank  pipe  (

Φ

150  mm)  is smaller  than  the  flue.  The  flue is 

Φ

200  mm  for  fireplaces with 

width 80cm and 90cm, and 250mm for fireplaces with width 100cm. 

If you cannot 

inspect or clean the chimney by yourself, contact your local  ARTE  ® dealer or a professional chimney 

sweep. 

If you experience a chimney fire, act promptly and: 

 

Close the air regulation (either setting to function  

 OFF or power failure)  

 

Evacuate the house 

 

Call the fire department 

-

 

Cleaning of heating water tubes 

Inspect regularly the heating water tubes, in order to remain clean and right flow of the gases to be ensured. In case 
that they need cleaning, remove the diaphragm of the central water tank pipe 

(Pic. 9.4.7)

 and  the flue gas baffles 

which are locat

ed at front line of tank’s tubes

 

(Pic. 9.4.8 & 9.4.9).

 

Use a common wire brush for the main tube. For the rest ones, use a cylindrical wire brush, which must be suitable for 
cleaning  6cm  diameter  tubes.  Also,  you  can  clean  through  the  main  tube,  the  area  that  is  above  the  tubes  of  the 
tank. 

-

 

Annual maintenance 

Before the operating season starts, perform a thorough cleaning, inspection and repair: 

 

Thoroughly clean the chimney and flue connector 

 

Inspect the chimney for damage and deterioration. In case of prefabricated chimney, replace any weak sections. 
In case of a masonry chimney, have a mason make any needed repairs 

 

Check the ceramic glass for any cracks and replace if needed 

 

Check if the door is airtight and the handle tight. Fix any problems. 

The flue,

 the water heating tubes and the flue gas baffles

 must be inspected at least 

once every two months during the operating season to determine if a creosote buildup 

has occurred. 

In that case, clean the: 

1) flue gas baffles 

2) flue, ensuring the for fire avoidance 

3) water heating tubes, ensuring right function and high performance

 

 

Содержание MENTOR hydro Series

Страница 1: ......

Страница 2: ......

Страница 3: ...m with open expansion tank 14 6 Operating Instructions 15 6 1 Before the first use of the ARTE MENTOR fireplace 15 6 2 About ARTE MENTOR fireplace 15 6 3 General information 16 When the fireplace paint dries 16 Incineration preparation 16 Combustion air intake 16 Power failure 16 ADF function 16 6 4 Usage of the detachable handle Cold handle 17 6 5 Adjustment of combustion air 18 Automatic regulat...

Страница 4: ... Removal of back vermiculites 28 Removal of bottom vermiculites Floor 29 Removal of bottom vermiculites Front side 29 Removal of diaphragm of the central water tank pipe 29 Removal of flue gas baffles 29 9 5 Drainage of water tank 30 9 6 Inactive fireplace for prolonged periods 30 10 Tips and tricks for resolving issues 31 11 Dimensions and technical specifications 32 12 Notes 34 ...

Страница 5: ... the sunny winter days It is the radiated heat that is transmitted by electromagnetic waves in the infrared range Even when the air is very cold you can feel the warm rays of the sun on your skin Another advantage of wood is that it is produced locally which creates local employment and more tax revenues stay in the province 2 2 Buying firewood Where can I get my firewood Regenerated ready to burn...

Страница 6: ...able to get your wood supplies during the summer months and store them to ensure better combustion quality during the winter Useful tips Always choose dry firewood Avoid wood that pops chestnut conifers such as cedar spruce and pine as they may damage your fireplace or the flue Pay attention to the size of the logs Good firewood must have been cut at least twice You should prefer oak beech olive w...

Страница 7: ... m3 7500W or 7 5 kW So for the main heating a 10kW appliance is enough Indicative combustion value with efficiency 80 Required amount relative to 1kg dry wood Fuel Unit kCal kW Firewood moisture 15 kg 3600 4 2 1 00 Firewood moisture 50 Kg 1850 2 2 1 95 Wood briquettes Kg 4000 5 0 0 84 Coal briquettes Kg 4800 5 6 0 75 Coal Kg 7700 8 9 0 47 Coke Kg 6780 7 9 0 53 Gas m3 7800 9 1 0 46 Diesel L 8500 9 ...

Страница 8: ...refully lift up the product and place it on the installation point making sure that the floor can withstand the weight of the device Also make sure you provide proper insulation in case the floor is built using flammable materials For the lifting use 2 shackles and a belt Pic 4 1 4 Not included inside the package Information about the weight of the device can be found at Table 11 2 The products th...

Страница 9: ...at the both counterweights right and left you can affect the function of the door Pic 5 1 4 For safety reasons and well function of the fireplace the door during its assembly at the factory is set to close at low speed Pic 5 1 1 Pic 5 1 2 Pic 5 1 3 Pic 5 1 4 5 2 Safety distances The combustion chamber opening must be AT LEAST 80cm away from any flammable materials that are inside the heat radiatio...

Страница 10: ...the construction material should be checked Materials such as cement with lime galvanized steel and rough or porous materials are contraindicated as they create issues in the correct operation of the fireplace Also a proper study for the flue size must be conducted because often old flues have quite large diameters This means that the amount of air draft is not proportional to the heat generated b...

Страница 11: ... m OVER THE RIDGE 1 50 m 1 30 m OVER THE ROOF 45ο 1 30 m 0 50 m OVER THE RIDGE 1 30 m 2 00 m OVER THE ROOF 60ο 1 20 m 0 50 m OVER THE RIDGE 1 20 m 2 60 m OVER THE ROOF Pic 5 5 4 Table 5 5 1 Chimney cap The chimney draft depends broadly on the adequacy of the cap So in case the chimney is built its exhaust diameter should be at least twice the inside diameter of the chimney Knowing that it is neces...

Страница 12: ... the back side of the fireplace adjusting a flexible aluminum tube on the Φ100 collar which is located at the right edge of the fireplace and close to the bottom Pic 5 7 1 For the wicket use a nozzle protected by a grille and a wire net The nozzle must intersect with the combustion chamber through the flexible tub which must be properly placed in order not to be covered Its minimum surface cannot ...

Страница 13: ...consult the drawing at Chapter 11 Dimensions technical specifications 5 9 Connection with the heating system The fireplace ARTE MENTOR can be installed to work individually or in collaboration with any another water heating device to be used for central or floor heating To ensure the safety of the device you must install an overheating safety Pic 5 9 1 in order to protect the system against possib...

Страница 14: ...the pipes to the circuit or seal if applicable the remaining joints you must use hemp or and thread glue An automatic vent valve must be placed for the bleed of the fireplace s tank This can be done in the following ways Installation of the automatic vent valve at the output hot water supply at the highest point like Pic 5 9 10 5 9 11 5 9 12 Or at the point 1 Pic 5 9 4 where is closed with a bushi...

Страница 15: ... valve sensor at point 6 Pic 5 9 4 In case the water temperature in the jacket exceeds 95oC the overheating safety valve will be activated and it will insert cold water in the independent overheating protection system located inside the water jacket thus rapidly dropping the water temperature and preventing the possibility of destroying the device without mixing the cold water with the water of th...

Страница 16: ...o be used simultaneously with a boiler tan for more safety of the circuit 13 Water pump 14 Automatic filling valve 15 Closed expansion tank 16 ARTE MENTOR fireplace 9 Fan coil heater 10 Radiator or heater mat 11 Temperature pressure gauge 12 Three way valve for by pass 5 Drainage 6 Water distribution box 7 Boiler 8 Hot domestic water 1 Automatic vent valve 2 Thermometer 3 Overheating safety valve ...

Страница 17: ... simultaneously with a boiler tan for more safety of the circuit 13 Water pump 14 Automatic filling valve 15 Closed expansion tank 16 ARTE MENTOR fireplace 9 Fan coil heater 10 Radiator or heater mat 11 Temperature pressure gauge 12 Three way valve for by pass 5 Drainage 6 Water distribution box 7 Boiler 8 Hot domestic water 1 Automatic vent valve 2 Thermometer 3 Overheating safety valve 4 Safety ...

Страница 18: ...r heater mat 11 Temperature pressure gauge 12 Three way valve for by pass 5 Drainage 6 Water distribution box 7 Boiler 8 Hot domestic water 1 Automatic vent valve 2 Thermometer 3 Overheating safety valve 4 ARTE MENTOR fireplace Pic 5 9 12 ARTE MENTOR fireplace is delivered with a stainless steel cooling coil already installed in which you must install a cold water supply Pic 5 9 6 so in case the w...

Страница 19: ...t 14 Automatic combustion air damper 2 Main door with double ceramic crystal 15 Water tank s drainage plug 3 Attach point for cold handle left right 16 Bottom vermiculite 1200kg m3 or cast iron 4 Log rolling guard 17 Vermiculite panels 750kg m3 or cast iron 5 Positioning wheels during installation 18 Ceramic blanket insulation 5 10cm with galvanized cover 6 Leveling and height adjustment feet 19 S...

Страница 20: ...eating although there is overheating protection Chapter 5 Pic 5 9 6 Therefore it is suggested the connection of the water pumps and the control panel with an uninterruptible power supply unit UPS in order the flow of the water to be prolonged till the fire in the chamber drops out It is suggested a pure sine wave UPS with minimum power of 1000VA to be used which will ensure uninterruptible operati...

Страница 21: ...ndle of your own choice or the ARTE s one you can order special tools from ARTE in order to adjust them The handle that you will choose from the market must be able to withstand high temperatures and agrees with the dimensions of Pic 6 4 3 Pic 6 4 3 Pic 6 4 4 In order to install the handle of your own choice unscrew the 4 screws at the bottom and remove the A B parts Pic 6 4 5 Screw the handle wit...

Страница 22: ...It regulates not only the start and end of the circulators but it also has the option when the user wishes it to give a periodic priority to the DHW pump in correlation to the HC pump Recurrent priority means that it alternately activates the HC pump for 45 seconds and then suspends it for the next 4 minutes thus resulting in heating the DHW faster It also has the option to shut down another heat ...

Страница 23: ... the CONFIRM 6 key The parameter field will start flashing and you can now change the value by pressing the 4 or 5 keys If any display has more than one parameter fields move between them with the TOGGLE 7 key and by pressing the CONFIRM 6 key register that change If you do not register the altered parameter within 10 seconds it will be ignored by the regulator The field will stop flashing and the...

Страница 24: ...tral position i e completely closed If this mode is selected the operation light 1 is off AUTO Activate the automatic cycle mode Ignition Operation Shutdown If this mode is selected the operation light 1 illuminates green during the operation of the fireplace and it turns of when it detects shutdown AUTO start finish This icon appears before the beginning and after the end of AUTO mode Press the F...

Страница 25: ...e default value 0 which means that the parameters are not available In the first view of the parameters display there is the definition of Parameters Level with the default value 0 which means that the parameters are not available After changing the level to 1 2 3 or 4 the following views on the display show the parameter values in the image on the right The last screen displays which ends the def...

Страница 26: ...EPLACE The automatic combustion air damper regulates the combustion depending on the water temperature inside the tank This thing allows you to deal only with the lighting and the supplying of the fire with wood To form an adequate layer of ash at the base of the fireplace use 1 2 kg of dry kindling the first time you light it If it is possible constantly maintain a layer of ash with thickness of ...

Страница 27: ... case call your chimney sweep In no case you must not try to light a bigger fire If smoke escapes from the fireplace ventilate the room immediately and call your chimney sweep DON T LIGHT THE FIREPLACE 7 4 Smoke escape in the room Check the following If for any reason you have left the door open during operation If the flue is absolutely airtight If the internal of the chimney is absolutely airtig...

Страница 28: ... maximum performance of secondary combustion The primary s intake air system from the bottom side of the combuston chamber in cooperation with the secondary s intake air system from the back of the combustion chamber supply uniformly the suitable quantity of preheated air which together with air curtain of the ceramic glass result in every place of the combustion chamber to receive the properamoun...

Страница 29: ...e stored in a closed container until cooled down or buried on the ground or dispersed somewhere Glass ARTE MENTOR fireplace has a double ceramic glass in the window of the combustion chamber in order pyrolysis to come faster and more heat to be kept inside the chamber supplying it at the water tank If the fireplace is generally operated at the correct temperature there should be little or no soot ...

Страница 30: ...fire to become a little less controllable An ARTE rope gasket kit is available on your local ARTE dealer Internal parts that need maintenance The components that are in the flame route consisting of the lining vermiculites the ceramic glass the vermiculite baffles and the steel baffle are subject to extreme stress because of the heat produced by the fire Occasionally some of these parts may have t...

Страница 31: ...The central water tank pipe Φ150 mm is smaller than the flue The flue is Φ200 mm for fireplaces with width 80cm and 90cm and 250mm for fireplaces with width 100cm If you cannot inspect or clean the chimney by yourself contact your local ARTE dealer or a professional chimney sweep If you experience a chimney fire act promptly and Close the air regulation either setting to function OFF or power fail...

Страница 32: ...ffle Removal of side vermiculites Removal of back vermiculites Pic 9 4 3 Remove the 1st baffle Pic 9 4 1 Lift up the vermiculite Νo 1 and then pull it inwards Slide the vermiculite Νο 2 backwards in order to be able to repeat the same procedure as for Vermiculite N0 1 Pic 9 4 4 After the removal of the side vermiculites lift up the back vermiculite and then pull it inwards Pic 9 4 1 Lift up the fr...

Страница 33: ...l it inwards Pic 9 4 6 After the removal of the floor vermiculites pull the vermiculite slightly right and then pull it inwards lifting its bottom face upwards Removal of diaphragm of the central water tank pipe Pic 9 4 7 Lift up the diaphragm rotate it left or right and remove it by pulling it downwards Removal of flue gas baffles Pic 9 4 8 Rotate the baffle Pic 9 4 9 Pull it downwards Repeat the...

Страница 34: ... the valve on order the drainage of the tank to start Pic 9 5 3 When the drainage is completed close the valve remove the hose that you connected towards the sewage and place again the parts that you removed bottom plate back cap baffle vermiculites etc 9 6 Inactive fireplace for prolonged periods IMPORTANT NOTICE If the fireplace is not used for some time clean it thoroughly and let the air contr...

Страница 35: ...function increase the air supply If you are at the AUTO function press F1 3 Small quantity of wood The wood is too wet The logs are too thick There is smoke coming out of the fireplace Check if there is adequate draft into the flue light a test fire Make sure there is sufficient air supply We hope you enjoy many years of carefree warmth with ARTE MENTOR fireplace Some initial experimentation with ...

Страница 36: ...ACE MENTOR Hydro 32 Page 11 DIMENSIONS AND TECHNICAL SPECIFICATIONS DIMENSION MODEL MENTOR ST80 Hydro MENTOR ST90 Hydro MENTOR ST100 Hydro A cm 80 90 100 B cm 22 4 25 2 C cm Φ20 Φ25 D cm 56 66 76 E cm 65 75 85 F cm 9 5 19 5 Table 11 1 ...

Страница 37: ...24 8 10 3 19 9 11 5 25 2 Fuel Wood Briquette Device dimensions W x D x H cm 80 63 160 90 63 160 100 63 160 Combustion chamber dimensions W x D x H cm 61 36 53 71 36 53 81 36 53 Flue draft Pa 12 2 Heated area m2 60 175 70 185 60 190 65 200 65 205 70 215 Weight Kg 370 405 460 External air inlet cm Ø 10 Smoke outlet diameter cm Ø 20 Ø 25 Minimum flue height m 4 Minimum heating area m2 45 45 50 The fi...

Страница 38: ...INSTALLATION USAGE MANUAL FIREPLACE MENTOR Hydro 34 Page 12 NOTES ...

Страница 39: ... αποκατάσταση ζημιών ή εξόδων για επενδύσεις ή φθορές που προκλήθηκαν σε πράγματα κινητά ή ακίνητα προκειμένου να αντικατασταθεί ελαττωματικό τμήμα του προϊόντος ενώ τυχόν κόστος μεταφοράς του προϊόντος ή ανταλλακτικού από την εταιρία στον καταναλωτή και το αντίστροφο ομοίως δεν περιλαμβάνεται στην εγγύηση και δεν βαρύνει την εταιρία Στα πλαίσια της εγγυήσεως αφαιρείται από τις υποχρεώσεις τις ετα...

Страница 40: ...κών με την αντίστοιχη κατά περίπτωση χρέωση για δέκα έτη από την αγορά του προϊόντος 1 7 Διαθεσιμότητα τεχνικών υπηρεσιών και ανταλλακτικών Η παρούσα εγγύηση παρέχεται ανεξάρτητα από οποιαδήποτε μη εξαιρούμενη νομική εγγύηση ή σχετική εθνική νομοθεσία που ισχύει όπως ενδεικτικά και όχι περιοριστικά τα σχετικά άρθρα του ΑΚ το ν 2251 1994 την ΥΑ Ζ1 2013 τις οδηγίες 2011 83 ΕΕ 1999 44 ΕΚ όπως αυτές ι...

Страница 41: ......

Страница 42: ......

Отзывы: