M

iscellaneous

 

P

anel

 

&

 

Cloc

k

 

Se

tt

ings+++++

 

Installer Code

 

P25E 

1E 

Installer Code - 

( Default = 000000)

 

 

Duress Digit 

P25E 

2E 

Duress Digit - 

Value 1-9 (Default = 0 Duress Function Disabled)

 

 

 

 

Dial Report Delay 

P25E 

3E 

Dial Report Delay - 

Value 0-255 seconds (Default = 0)

 

 

Radio Detector Supervised Timer 

P25E 

4E 

Radio Detector Supervised Timer - 

0-9999 Minutes (Default = 240 Minutes [4 Hours])

 

 

Two Trigger Timer 

P25E 

5E 

Two Trigger Timer - 

Value 0-255 Seconds (Default = 60 Sec)

 

 

Mains Fail Reporting Delay 

P25E 

6E 

Mains Fail Reporting Delay - 

Value 0-9999 Seconds (Default = 600 Sec)

 

 

Receiver Fail Delay 

P25E 

7E 

Receiver Fail Delay - 

Value 0-9999 Seconds (Default = 0 Sec-Disabled)

 

 

Upload/Download Site Code Number 

P25E 

8E 

Upload/Download Site Code Number - 

Up to 

8 Characters (Default = None)

 

 

Temporary Output Disable 

P25E 

9E 

Temporary Output Disable -  

Output 1-8 

 

 

Miscellaneous Panel Options 

P25E 

10E 

Misc. Panel Options 

Miscellaneous Options

 

 

 

 

(Default = 2,6)

 

1 = Panel Tamper is 2k2 EOL

 

 

 

 

2 = Direct access to program mode for the installer code. 

 

 

3 = Disable Mains Fail Test

 

 

 

4 = Listen-in to O/P # 1 Low Volume

 

 

 

 

5 = Receiver Fail/RF Jammed Lockout 

 

 

6 = Send output information to keypad bus 

 

 

7 = Cannot arm if the system battery is low  

 

 

8 = Installer Lockout 

Installer Options 

P25E 

11E 

Installer Options 

 

 

 

 

(Default = All Off)

 

1 = Entry to installer mode resets confirmed alarms

 

 

 

 

2 = Entry to installer mode resets tamper alarms 

 

 

3 = Entry to installer mode resets low battery alarms

 

 

 

4 = Entry to installer mode resets supervisory alarms 

 

 

5 = Cannot Arm if there is a keypad Fault 

 

 

6 = Cannot Arm if there is a Telephone Line Failure or Comms Fault 

 

 

7 = 10 Incorrect Code Attempts locks out the keypad for 90 Seconds 

 

 

8 = User Codes Must be 4-6 digits long 

User Options 

P25E 

12E 

User Options (NOTE: This Option can ONLY be accessed from Client Mode)

 

 

 

(Default = All Off)

 

1 = Hide User Codes from Installer 

 
P25E 

13E 

Misc. User Options 

Miscellaneous User Options

 

 

 

 

(Default = )

 

1 = Code Required to View Memory

 

 

 

 

2 = Cancel Handover Zone Function in Stay Mode 

 

 

3 = Output Control from Keypad is Disabled when Armed

 

 

 

4 = Keypad Codes are Disabled During Entry Delay

 

 

 

 

5 = No Keypad Indications while Armed 

 

 

6 = Monitored KP Buss Output Board 

 

 

7 = Enable Keypad Tamper Switch Alarms 

 

 

8 = Limit Events & Dialler to 3 of any one type 

 

Setting Real Time Clock

 

P26E 

1E 

Real Time Hour/Minute  - 

Value 0-2359

 

 

 

 

 

 

 

 

P26E 

2E 

Real Time Day of Week  - 

Value 1-7 (1=Sunday, 2=Monday ,etc)

 

P26E 

3E 

Real Time Date/Month/Year   - 

Value DDMMYY (eg 020904 = 2nd Sept 2004)

 

P26E 

4E 

Daylight  Saving  is  Active 

(If LED #1 is On, Daylight Saving is currently active) Turn this bit ON if you are in 

Daylight    

Saving Time when the panel is installed.

 

Daylight Saving settings 

P27E 

1E 

Daylight Saving Start Sunday  - 

Value 0-5 - Default = 5 (0 = DLS disabled, 5 = last Sunday of Month)  

 

2E 

Daylight Saving End Sunday  - 

Value 0-5 - Default = 1 (0 = DLS disabled, 5 = last Sunday of Month)

 

Содержание Elite S V9

Страница 1: ...Proudly Designed and Manufactured in New Zealand ProgramSummary Guide ELITE S Version Arrowhead Alarm Products Ltd 8 16ZoneControlCommunicator V9...

Страница 2: ...7 8 2 User can Change All Codes Default User 2 100 All Off 3 User can Allow Access to Installer Mode Edit all Codes 4 User can Change Telephone Numbers 5 User can Change the Clock 6 User can Change D...

Страница 3: ...rn off Output 6 7 User Can Turn off Output 7 8 User Can Turn off Output 8 Radio Pendant Panic Alarm to an Output P15E 21 100E Radio 21 100 Panic Alarm to an O P 1 Radio panic to Output 1 Default 1 2 2...

Страница 4: ...firmed alarms 2 Entry to installer mode resets tamper alarms 3 Entry to installer mode resets low battery alarms 4 Entry to installer mode resets supervisory alarms 5 Cannot Arm if there is a keypad F...

Страница 5: ...ing 4 Pulse Output on Kiss off Following a Zone Alarm 5 Output Disabled when P25E3E timer is running 6 Spare 7 Spare 8 Spare Programming Output Options D P37E 1 8E Options D for Outputs 1 8 1 Siren Dr...

Страница 6: ...fault All Off 2 Area B Area A B Pendant or Access Tag Arm Chirp to Output P50E 1 2E Area A B Arm Chirp to Output Value 1 8 for Outputs 1 8 1 Area A Default All Off One chirp to the output for arm 2 Ar...

Страница 7: ...s A B 2 Area B Area A B Armed Mode Exit Delay to Output P65E 1 2E Area A B Armed Exit Delay to Output Value 1 8 for Outputs 1 8 1 Area A Default All Off 2 Area B Area A B Stay Mode Exit Delay to Outpu...

Страница 8: ...A Button can Stay Mode Arm 3 A Button can Disarm at All Times 4 A Button can Disarm Stay Mode at All Times 5 A Button can Reset Alarms 6 A Button can Arm Latchkey Mode 7 A Button can Disarm During Ex...

Страница 9: ...will turn on Output 2 3 The Keypad Duress Alarm will turn on Output 3 4 The Keypad Duress Alarm will turn on Output 4 5 The Keypad Duress Alarm will turn on Output 5 6 The Keypad Duress Alarm will tur...

Страница 10: ...KP 4 5 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 5 6 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 6 7 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 7 8 A Wr...

Страница 11: ...ne will Not Report 24 hour Alarms via Dialler 7 Pulse Output on Kiss off Following an alarm 8 Exit Terminator Programming Zone EOL End of line Options P125E 1 8E Programming Zone EOL Options 0 Short C...

Страница 12: ...On Output 1 2 A Chime Zone Alarm will Turn On Output 2 3 A Chime Zone Alarm will Turn On Output 3 4 A Chime Zone Alarm will Turn On Output 4 5 A Chime Zone Alarm will Turn On Output 5 6 A Chime Zone A...

Страница 13: ...eep Keypad 2 3 A Radio Supervise Alarm will Beep Keypad 3 4 A Radio Supervise Alarm will Beep Keypad 4 5 A Radio Supervise Alarm will Beep Keypad 5 6 A Radio Supervise Alarm will Beep Keypad 6 7 A Rad...

Страница 14: ...E Zone Bypass Alarm 4 2 Reporting Code Two digit value from 00 FF Zone Bypass 4 2 Restore Reporting Codes P156E 1 16E Zone Bypass Restore 4 2 Code Two digit value from 00 FF Zone Alarm Contact ID Repo...

Страница 15: ...ed Alarm to output 2 3 Zone Confirmed Alarm to output 3 4 Zone Confirmed Alarm to output 4 5 Zone Confirmed Alarm to output 5 6 Zone Confirmed Alarm to output 6 7 Zone Confirmed Alarm to output 7 8 Zo...

Страница 16: ...5 Enabled Throughout the call in Armed State only 6 Enabled Throughout the call in Stay Mode State only 7 Listen in Enabled when the panel answers a call 8 Enabled at All Times Dialling Pre fix Number...

Страница 17: ...phone Number P184E 1 8E Maximum Dial Attempts per Telephone Number Value 0 99 Default 20 Dialler Reporting Options A P186E 1 8E Dialler Options A 1 Report Mains Failure Default All On 2 Report Battery...

Страница 18: ...ote Arm Disarm 4 2 Reporting Codes P195E 7E 4 2 Code for Remote Arming Full Arm or Stay Mode Arm Two digit value from 00 FF P195E 8E 4 2 Code for Remote Disarm Two digit value from 00 FF Duress Alarm...

Страница 19: ...A Medical Alarm SIA Reporting Code P197E 3E Medical Alarm SIA Reporting Code Default value 5 Medical Alarm Event Code MA Panel Diagnostic Default Options Display Panel Software Version Number P200E 1E...

Страница 20: ...ck Arm 408 000 Arm Disarm by single button Arm Disarm by user code 401 001 to 100 Arm Disarm by User 1 100 Arm Disarm by Radio key 400 021 to 100 Arm Disarm by Radio User 21 100 Arm Disarm by Key swit...

Страница 21: ...Armed by Time Zone CA OA Stay Mode Armed by User Pendant KS STAY Button CG OG Fail to Arm by Time Zone CI Program Mode Entry Exit LB LX Checksum Fail Corrupt EEPROM Data YF Time Changed JT Keypad Bus...

Страница 22: ...models only inhibit arming on a battery low 3 Option 5 at P25E11E was added Option 5 inhibits arming during a missing keypad alarm 4 Option 6 at P25E11E was added Option 6 inhibits arming during a tel...

Страница 23: ...11E were all defaulted to 1 which meant all of those events would report when set to Domestic or Voice reporting format If they were not required the value needed to be set to 0 to stop it reporting T...