M
iscellaneous
P
anel
&
Cloc
k
Se
tt
ings+++++
Installer Code
P25E
1E
Installer Code -
( Default = 000000)
Duress Digit
P25E
2E
Duress Digit -
Value 1-9 (Default = 0 Duress Function Disabled)
Dial Report Delay
P25E
3E
Dial Report Delay -
Value 0-255 seconds (Default = 0)
Radio Detector Supervised Timer
P25E
4E
Radio Detector Supervised Timer -
0-9999 Minutes (Default = 240 Minutes [4 Hours])
Two Trigger Timer
P25E
5E
Two Trigger Timer -
Value 0-255 Seconds (Default = 60 Sec)
Mains Fail Reporting Delay
P25E
6E
Mains Fail Reporting Delay -
Value 0-9999 Seconds (Default = 600 Sec)
Receiver Fail Delay
P25E
7E
Receiver Fail Delay -
Value 0-9999 Seconds (Default = 0 Sec-Disabled)
Upload/Download Site Code Number
P25E
8E
Upload/Download Site Code Number -
Up to
8 Characters (Default = None)
Temporary Output Disable
P25E
9E
Temporary Output Disable -
Output 1-8
Miscellaneous Panel Options
P25E
10E
Misc. Panel Options
Miscellaneous Options
(Default = 2,6)
1 = Panel Tamper is 2k2 EOL
2 = Direct access to program mode for the installer code.
3 = Disable Mains Fail Test
4 = Listen-in to O/P # 1 Low Volume
5 = Receiver Fail/RF Jammed Lockout
6 = Send output information to keypad bus
7 = Cannot arm if the system battery is low
8 = Installer Lockout
Installer Options
P25E
11E
Installer Options
(Default = All Off)
1 = Entry to installer mode resets confirmed alarms
2 = Entry to installer mode resets tamper alarms
3 = Entry to installer mode resets low battery alarms
4 = Entry to installer mode resets supervisory alarms
5 = Cannot Arm if there is a keypad Fault
6 = Cannot Arm if there is a Telephone Line Failure or Comms Fault
7 = 10 Incorrect Code Attempts locks out the keypad for 90 Seconds
8 = User Codes Must be 4-6 digits long
User Options
P25E
12E
User Options (NOTE: This Option can ONLY be accessed from Client Mode)
(Default = All Off)
1 = Hide User Codes from Installer
P25E
13E
Misc. User Options
Miscellaneous User Options
(Default = )
1 = Code Required to View Memory
2 = Cancel Handover Zone Function in Stay Mode
3 = Output Control from Keypad is Disabled when Armed
4 = Keypad Codes are Disabled During Entry Delay
5 = No Keypad Indications while Armed
6 = Monitored KP Buss Output Board
7 = Enable Keypad Tamper Switch Alarms
8 = Limit Events & Dialler to 3 of any one type
Setting Real Time Clock
P26E
1E
Real Time Hour/Minute -
Value 0-2359
P26E
2E
Real Time Day of Week -
Value 1-7 (1=Sunday, 2=Monday ,etc)
P26E
3E
Real Time Date/Month/Year -
Value DDMMYY (eg 020904 = 2nd Sept 2004)
P26E
4E
Daylight Saving is Active
(If LED #1 is On, Daylight Saving is currently active) Turn this bit ON if you are in
Daylight
Saving Time when the panel is installed.
Daylight Saving settings
P27E
1E
Daylight Saving Start Sunday -
Value 0-5 - Default = 5 (0 = DLS disabled, 5 = last Sunday of Month)
2E
Daylight Saving End Sunday -
Value 0-5 - Default = 1 (0 = DLS disabled, 5 = last Sunday of Month)