![Arrowhead Alarm Products Elite S V9 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/arrowhead-alarm-products/elite-s-v9/elite-s-v9_program-manual_2976794010.webp)
Page 10
Manually Operated Fire Alarm Beeps to Keypads
P91E
1-8E
Fire Alarm Beeps to Keypads
(Default = All On)
1 = A Fire Alarm at the selected keypad will Beep KP # 1
2 = A Fire Alarm at the selected keypad will Beep KP # 2
3 = A Fire Alarm at the selected keypad will Beep KP # 3
4 = A Fire Alarm at the selected keypad will Beep KP # 4
5 = A Fire Alarm at the selected keypad will Beep KP # 5
6 = A Fire Alarm at the selected keypad will Beep KP # 6
7 = A Fire Alarm at the selected keypad will Beep KP # 7
8 = A Fire Alarm at the selected keypad will Beep KP # 8
Manually Operated Medical Alarm Beeps to Keypads
P92E
1-8E
Medical Alarm Beeps to Keypads
(Default = All On)
1 = A Medical Alarm at the selected keypad will Beep KP # 1
2 = A Medical Alarm at the selected keypad will Beep KP # 2
3 = A Medical Alarm at the selected keypad will Beep KP # 3
4 = A Medical Alarm at the selected keypad will Beep KP # 4
5 = A Medical Alarm at the selected keypad will Beep KP # 5
6 = A Medical Alarm at the selected keypad will Beep KP # 6
7 = A Medical Alarm at the selected keypad will Beep KP # 7
8 = A Medical Alarm at the selected keypad will Beep KP # 8
Wrong Code or Keypad Tamper Switch Alarm Beeps to Keypads
P93E
1-8E
Wrong Code or Keypad Tamper Switch Alarm Beeps to Keypads
(Default = All On)
1 = A Wrong Code or KP Tamper Alarm at Keypad 1-8 will Beep KP # 1
2 = A Wrong Code or KP Tamper Alarm at Keypad 1-8 will Beep KP # 2
3 = A Wrong Code or KP Tamper Alarm at Keypad 1-8 will Beep KP # 3
4 = A Wrong Code or KP Tamper Alarm at Keypad 1-8 will Beep KP # 4
5 = A Wrong Code or KP Tamper Alarm at Keypad 1-8 will Beep KP # 5
6 = A Wrong Code or KP Tamper Alarm at Keypad 1-8 will Beep KP # 6
7 = A Wrong Code or KP Tamper Alarm at Keypad 1-8 will Beep KP # 7
8 = A Wrong Code or KP Tamper Alarm at Keypad 1-8 will Beep KP # 8
Chime Alarm Beep Time at a Keypad
P94E
1-8E
The Time the Chime Alarm will sound at Each Keypad
-
Value =0-255 1/10th sec
(Default = 20 which is 2 Seconds)
Proximity Reader LED to Output Mapping
P98E
1-8E
Proximity Reader LED to Output Mapping
(Default = None)
1 = Proximity Reader 1-8 LED will follow the state of Output # 1
2 = Proximity Reader 1-8 LED will follow the state of Output # 2
3 = Proximity Reader 1-8 LED will follow the state of Output # 3
4 = Proximity Reader 1-8 LED will follow the state of Output # 4
5 = Proximity Reader 1-8 LED will follow the state of Output # 5
6 = Proximity Reader 1-8 LED will follow the state of Output # 6
7 = Proximity Reader 1-8 LED will follow the state of Output # 7
8 = Proximity Reader 1-8 LED will follow the state of Output # 8
Learn Proximity Reader Keypad Address Number
P99E
1-8E
Learn Proximity Reader Keypad Address Number
-
Value = Keypad Address 1-8
+++++
K
ey
-
swi
t
ches+++++
Key-switch Area Assignment
P111E 1-2E
K/S 1 & 2 assigned to Areas A or B -
1 = Assigned to Area “A”
(1 = K/S # 1) (Default K/S # 1 = 1)
2 = Assigned to Area “B”
(2 = K/S # 2) (Default K/S # 2 = 2)
Key-switch Access & Operational Options
P112E 1-2E
K/S 1 & 2 Access & Operational Options
1 = K/S can Arm Area
(1 = K/S # 1)
(Default = All Off)
2 = K/S can arm Stay Mode
(2 = K/S # 2)
3 = K/S can Disarm Area
4 = K/S can disarm Stay Mode
5 = K/S has Security Guard Options
6 = K/S will Arm Latchkey Mode
7 = Key-switch is N/O (If turned off the K/S is N/C)
8 = Key-switch is Momentary (If turned off the K/S is Latching)