Software change Update Notice
Software Update V9.03 August 2006
The following new features have been added in V9.03
1– Code required to View memory P4E option 8 and P25E option 1
2– Radio pendant only works during entry delay for disarm P8E option 4
3– User codes 21-100 can be a unique duress code P8E option 5
4– Cancel handover feature in Stay mode only P25E option 2
5– Keypad output control disabled when armed P25E option 3
6– User codes disabled during entry delay P25E option 4
7– Blank keypad display when armed P25E option 5
8– Pulse an output on kiss-off of a zone alarm P36E option 4 & P124E option 7
9– Output Chime timer can be in minutes P37E option 2 (was previously only reset time)
10– Stay mode armed confirmation beep to keypad P72E option 8
11– Zone lockout function has been removed P123E option 6
12– Zone can pulse output on kiss-off P124E option 7 & P36E option 4
13– A zone can be used to terminate the exit delay P124E option 8
14– The zone re-trigger timer has been replaced with a re-trigger count P146E
15– A new SIA reporting format has been added P182E option 10
16– Some new dialler reporting options have been added P189E options 6 & 7
17– SIA reporting codes can be edited P196E & P197E
Software Update V9.03B September 2006
The following new feature has been added in V9.03B
1– The “Dial Report Delay” timer at P25E3E only worked for zone alarms in full arm mode. In version 9.03B the dial
report delay also now applies to zone alarms in Stay Mode.
Software Update V9.04 November 2006
The following new features were added in V9.04
1 - Option 5 at P25E10E was modified to include “RF Jammed” as part of the arm lockout.
2 - Option 7 at P25E10E was modified to include AC fail as part of the arm lockout. Only available on “SIEM” models.
All other models only inhibit arming on a battery low.
3 - Option 5 at P25E11E was added. Option 5 inhibits arming during a missing keypad alarm.
4 - Option 6 at P25E11E was added. Option 6 inhibits arming during a telephone line fault or Comms fault (failure to
get a kissoff).
5 - Option 7 at P25E11E was added. Option 7 increase the wrong code keypad tamper count from 4 to 10 and locks
out the keypad for 90 seconds.
6 - Option 5 at P175E2E was added. Option 5 changes the test time period (P175E5E) from hours to days.
7 - A new monitoring format was added at P182E. The new option is SIA Slow format (option 11).
8 - Option 8 at P189E was added. Option 8 allows reporting of the RF jammed alarm.
Software Update V9.05 January 2007
The following new features were added in V9.05
1 - Option 4 at P37E was added to disable outputs during two way voice mode.
2 - Option 8 at P175E2E was added to allow the panel to auto-answer after 1 ring if set up to do full duplex two way
voice using the call-back option.
3—Option 5 at P183E was added to allow for direct on-line two way voice following reporting of an alarm event.
Software Update V9.06.5 September 2007
The following new feature was added in V9.07.7
1 - Option 14 was added at P200E to allow the RSSI (received signal strength) to be displayed at LCD keypads with
software version V208.5 or greater. It can also be used with the Icon LCD keypad. The signal strength reading is dis-
played along with the User or Zone number that was received at the time. For the readings to be available to the con-
trol panel an RX-16 MF receiver must be connected to the alarm system.
Software Update V9.07.7 February 2008
The following new feature was added in V9.07.7
1 - Option 7 at P25E13E was added to disable alarms from keypad tamper switches. By default the option is turned
off which means all keypad tampers will be ignored.
Software Update V9.07.12 March 2008
1 - The New Zealand Daylight saving defaults were changed.
2 - The panel supports the TCP/IP module.