Z

ones+++++

 

Programming Zones to Areas  

P121E  1-16E 

Assigning Zones to Areas A or B 

  

1 = Assigned to Area “A”

 

 

 

 

(Default = 1)

 

2 = Assigned to Area “B”

 

Programming Zone Options A

 

P122E  1-16E 

Programming Zone Options A 

1 = Zone is Active

 

 

 

 

(Default Zone 1-4 = 1,6,7,8)

 

2 = Zone is N/O (Off = N/C)

 

 

 

 

(Default Zone 5-8 = 1,7,8)

 

3 = Not an Exit Delay Zone

 

 

 

 

(Default Zone 9-16 = 7,8)

 

4 = Keypad Zone

 

 

 

 

5 = Zone is a Radio Zone

 

 

 

  

6 = Zone is a Stay Mode Zone

 

 

 

 

7 = Zone can be Manually Bypassed

 

 

 

 

8 = Zone can be Auto-Bypassed

 

Programming Zone Options B

 

P123E  1-16E 

Programming Zone Options B 

1 = Zone is a Handover Zone

 

 

 

 

(Default = All Off)

 

2 = Zone is a Two Trigger Zone

 

 

 

 

3 = Zone is a 24 Hour Zone

 

 

 

 

4 = Zone is a 24 Hour Auto-reset Zone

 

 

 

 

5 = Zone is a 24 Hour Fire Zone

 

 

 

  

6 = Spare

 

 

 

 

7 = Zone is a Chime Zone

 

 

 

 

8 = Zone is a Permanent Chime Zone

 

Programming Zone Options C

 

P124E  1-16E 

Programming Zone Options C 

1 = Can Arm if Zone is not Ready

 

 

 

(Default = 2)

 

2 = Will Send Multiple Reports via Dialler

 

 

 

 

3 = Sensor-Watch Zone

 

 

 

 

4 = Zone is on Soak Test

 

 

 

 

5 = Zone will report to Area B Account Number

 

 

 

  

6 = Zone will Not Report 24 hour Alarms via Dialler

   

 

 

7 = Pulse Output on Kiss-off Following an alarm

 

 

 

8 = Exit Terminator 

Programming Zone EOL (End-of-line) Options 

P125E  1-8E 

Programming Zone EOL Options 

0 = Short Circuit

 

 

 

 

(Default = 3)

 

1 = 1k

 

 

 

 

2 = 1k5

 

 

 

 

3 = 2k2

 

 

 

 

4 = 3k3

 

 

 

  

5 = 3k9

 

 

 

 

6 = 4k7

 

 

 

7 = 5k6 

 

 

 

8 = 6k8

 

 

 

 

9 = 10k

 

 

 

 

10 = 12k

 

 

 

 

11 = 22k

 

 

 

  

12 = 2k2 / 4k7

 

 

 

 

13 = 3k3 / 6k8

 

 

 

14 = 2k2 / 4k7 / 8k2 

 

 

15 = 4k7 / 8k2

 

Programming Zone Response 

P126E  1-8E 

Programming Zone Response 

1 to 8 Vibration mode 

 

 

 

 

(Default = 9)

 

  (Zone EOL-P125E, for Vibration Mode  MUST be type 3  

 

 

 

only ) 

 

 

 

 

1 = highest and 8 is lowest sensitivity level. 

 

 

 

9 to 26 Normal zone mode 

 

 

 

    Response time = approx 200ms –1sec

 

Programming the Radio Zone Detector Type

 

P127E  1-16E 

Programming the Radio Zone Type from the List

 - 

Value = 1-35

 

 

 

 

(Default = 4) 

0 = Generic

 

 

 

 

1 = Crow Merlin PIR (supervised signal ignored)

 

 

 

 

2 = Crow Merlin PIR (supervised signal active)

 

 

 

 

3 = Freelink with checksum (supervised signal active)

 

 

 

 

4 = Freelink with checksum (non-supervised) 

 

 

5 = Crow AE Series Battery low

 

 

 

 

6 = Crow AE Radio Reed Switch

 

 

 

11 = Ness Devices battery Low

 

 

 

 

12 = Ness Radio Reed Switch 

 

 

 

 

31 = Visonic K900 Radio PIR 

 

 

32 = Visonic Powercode (supervised signal ignored) 

 

 

33 = Visonic Powercode (supervised signal active) 

 

 

34 = Siemens (supervised signal ignored) 

 

 

35 = Siemens (supervised signal active)

 

 

Содержание Elite S V9

Страница 1: ...Proudly Designed and Manufactured in New Zealand ProgramSummary Guide ELITE S Version Arrowhead Alarm Products Ltd 8 16ZoneControlCommunicator V9...

Страница 2: ...7 8 2 User can Change All Codes Default User 2 100 All Off 3 User can Allow Access to Installer Mode Edit all Codes 4 User can Change Telephone Numbers 5 User can Change the Clock 6 User can Change D...

Страница 3: ...rn off Output 6 7 User Can Turn off Output 7 8 User Can Turn off Output 8 Radio Pendant Panic Alarm to an Output P15E 21 100E Radio 21 100 Panic Alarm to an O P 1 Radio panic to Output 1 Default 1 2 2...

Страница 4: ...firmed alarms 2 Entry to installer mode resets tamper alarms 3 Entry to installer mode resets low battery alarms 4 Entry to installer mode resets supervisory alarms 5 Cannot Arm if there is a keypad F...

Страница 5: ...ing 4 Pulse Output on Kiss off Following a Zone Alarm 5 Output Disabled when P25E3E timer is running 6 Spare 7 Spare 8 Spare Programming Output Options D P37E 1 8E Options D for Outputs 1 8 1 Siren Dr...

Страница 6: ...fault All Off 2 Area B Area A B Pendant or Access Tag Arm Chirp to Output P50E 1 2E Area A B Arm Chirp to Output Value 1 8 for Outputs 1 8 1 Area A Default All Off One chirp to the output for arm 2 Ar...

Страница 7: ...s A B 2 Area B Area A B Armed Mode Exit Delay to Output P65E 1 2E Area A B Armed Exit Delay to Output Value 1 8 for Outputs 1 8 1 Area A Default All Off 2 Area B Area A B Stay Mode Exit Delay to Outpu...

Страница 8: ...A Button can Stay Mode Arm 3 A Button can Disarm at All Times 4 A Button can Disarm Stay Mode at All Times 5 A Button can Reset Alarms 6 A Button can Arm Latchkey Mode 7 A Button can Disarm During Ex...

Страница 9: ...will turn on Output 2 3 The Keypad Duress Alarm will turn on Output 3 4 The Keypad Duress Alarm will turn on Output 4 5 The Keypad Duress Alarm will turn on Output 5 6 The Keypad Duress Alarm will tur...

Страница 10: ...KP 4 5 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 5 6 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 6 7 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 7 8 A Wr...

Страница 11: ...ne will Not Report 24 hour Alarms via Dialler 7 Pulse Output on Kiss off Following an alarm 8 Exit Terminator Programming Zone EOL End of line Options P125E 1 8E Programming Zone EOL Options 0 Short C...

Страница 12: ...On Output 1 2 A Chime Zone Alarm will Turn On Output 2 3 A Chime Zone Alarm will Turn On Output 3 4 A Chime Zone Alarm will Turn On Output 4 5 A Chime Zone Alarm will Turn On Output 5 6 A Chime Zone A...

Страница 13: ...eep Keypad 2 3 A Radio Supervise Alarm will Beep Keypad 3 4 A Radio Supervise Alarm will Beep Keypad 4 5 A Radio Supervise Alarm will Beep Keypad 5 6 A Radio Supervise Alarm will Beep Keypad 6 7 A Rad...

Страница 14: ...E Zone Bypass Alarm 4 2 Reporting Code Two digit value from 00 FF Zone Bypass 4 2 Restore Reporting Codes P156E 1 16E Zone Bypass Restore 4 2 Code Two digit value from 00 FF Zone Alarm Contact ID Repo...

Страница 15: ...ed Alarm to output 2 3 Zone Confirmed Alarm to output 3 4 Zone Confirmed Alarm to output 4 5 Zone Confirmed Alarm to output 5 6 Zone Confirmed Alarm to output 6 7 Zone Confirmed Alarm to output 7 8 Zo...

Страница 16: ...5 Enabled Throughout the call in Armed State only 6 Enabled Throughout the call in Stay Mode State only 7 Listen in Enabled when the panel answers a call 8 Enabled at All Times Dialling Pre fix Number...

Страница 17: ...phone Number P184E 1 8E Maximum Dial Attempts per Telephone Number Value 0 99 Default 20 Dialler Reporting Options A P186E 1 8E Dialler Options A 1 Report Mains Failure Default All On 2 Report Battery...

Страница 18: ...ote Arm Disarm 4 2 Reporting Codes P195E 7E 4 2 Code for Remote Arming Full Arm or Stay Mode Arm Two digit value from 00 FF P195E 8E 4 2 Code for Remote Disarm Two digit value from 00 FF Duress Alarm...

Страница 19: ...A Medical Alarm SIA Reporting Code P197E 3E Medical Alarm SIA Reporting Code Default value 5 Medical Alarm Event Code MA Panel Diagnostic Default Options Display Panel Software Version Number P200E 1E...

Страница 20: ...ck Arm 408 000 Arm Disarm by single button Arm Disarm by user code 401 001 to 100 Arm Disarm by User 1 100 Arm Disarm by Radio key 400 021 to 100 Arm Disarm by Radio User 21 100 Arm Disarm by Key swit...

Страница 21: ...Armed by Time Zone CA OA Stay Mode Armed by User Pendant KS STAY Button CG OG Fail to Arm by Time Zone CI Program Mode Entry Exit LB LX Checksum Fail Corrupt EEPROM Data YF Time Changed JT Keypad Bus...

Страница 22: ...models only inhibit arming on a battery low 3 Option 5 at P25E11E was added Option 5 inhibits arming during a missing keypad alarm 4 Option 6 at P25E11E was added Option 6 inhibits arming during a tel...

Страница 23: ...11E were all defaulted to 1 which meant all of those events would report when set to Domestic or Voice reporting format If they were not required the value needed to be set to 0 to stop it reporting T...

Отзывы: