Page 11
+++++
Z
ones+++++
Programming Zones to Areas
P121E 1-16E
Assigning Zones to Areas A or B
1 = Assigned to Area “A”
(Default = 1)
2 = Assigned to Area “B”
Programming Zone Options A
P122E 1-16E
Programming Zone Options A
1 = Zone is Active
(Default Zone 1-4 = 1,6,7,8)
2 = Zone is N/O (Off = N/C)
(Default Zone 5-8 = 1,7,8)
3 = Not an Exit Delay Zone
(Default Zone 9-16 = 7,8)
4 = Keypad Zone
5 = Zone is a Radio Zone
6 = Zone is a Stay Mode Zone
7 = Zone can be Manually Bypassed
8 = Zone can be Auto-Bypassed
Programming Zone Options B
P123E 1-16E
Programming Zone Options B
1 = Zone is a Handover Zone
(Default = All Off)
2 = Zone is a Two Trigger Zone
3 = Zone is a 24 Hour Zone
4 = Zone is a 24 Hour Auto-reset Zone
5 = Zone is a 24 Hour Fire Zone
6 = Spare
7 = Zone is a Chime Zone
8 = Zone is a Permanent Chime Zone
Programming Zone Options C
P124E 1-16E
Programming Zone Options C
1 = Can Arm if Zone is not Ready
(Default = 2)
2 = Will Send Multiple Reports via Dialler
3 = Sensor-Watch Zone
4 = Zone is on Soak Test
5 = Zone will report to Area B Account Number
6 = Zone will Not Report 24 hour Alarms via Dialler
7 = Pulse Output on Kiss-off Following an alarm
8 = Exit Terminator
Programming Zone EOL (End-of-line) Options
P125E 1-8E
Programming Zone EOL Options
0 = Short Circuit
(Default = 3)
1 = 1k
2 = 1k5
3 = 2k2
4 = 3k3
5 = 3k9
6 = 4k7
7 = 5k6
8 = 6k8
9 = 10k
10 = 12k
11 = 22k
12 = 2k2 / 4k7
13 = 3k3 / 6k8
14 = 2k2 / 4k7 / 8k2
15 = 4k7 / 8k2
Programming Zone Response
P126E 1-8E
Programming Zone Response
1 to 8 Vibration mode
(Default = 9)
(Zone EOL-P125E, for Vibration Mode MUST be type 3
only )
1 = highest and 8 is lowest sensitivity level.
9 to 26 Normal zone mode
Response time = approx 200ms –1sec
Programming the Radio Zone Detector Type
P127E 1-16E
Programming the Radio Zone Type from the List
-
Value = 1-35
(Default = 4)
0 = Generic
1 = Crow Merlin PIR (supervised signal ignored)
2 = Crow Merlin PIR (supervised signal active)
3 = Freelink with checksum (supervised signal active)
4 = Freelink with checksum (non-supervised)
5 = Crow AE Series Battery low
6 = Crow AE Radio Reed Switch
11 = Ness Devices battery Low
12 = Ness Radio Reed Switch
31 = Visonic K900 Radio PIR
32 = Visonic Powercode (supervised signal ignored)
33 = Visonic Powercode (supervised signal active)
34 = Siemens (supervised signal ignored)
35 = Siemens (supervised signal active)