Arrowhead Alarm Products Elite S V9 Скачать руководство пользователя страница 2

Page 2 

ELITE S PROGRAM SUMMARY GUIDE

 

+++++

U

sers+++++

 

Programming User Codes 

P1E 

1-100E 

User Code 1-100 - 

Default for User Code # 1 (P1E1E)   = 123   Codes can be  1-6 or 4-6 digits

(where 1E = User Code #1 to 100E = User Code #100) 

NOTE: 

The 100 Users can be keypad Code, Radio or Access key Users. They can be mixed but the Maximum is 100 Users. 

The User type MUST be set to “0” (P2E User# E) for a code to be entered at the above address

.

 

User Type (Code/Radio/Access Tag-Card) 

P2E 

1-100E 

User # 1-100 Type - 

  

0 = Keypad Code User {PIN}

 

 

 

(Default = 0)

 

1 = Radio User (Users 21-100 only) 

 

 

 

2 = Access Tag/Card User 

 

 

 

3 = Both Code and Access Tag/Card User {Tag + PIN) 

 

 

 

4 = Either Code or Access Tag/Card User {Tag or PIN}

 

User Area Assignment 

P3E 

1-100E 

User # 1-100 Area - 

  

1 = Assigned to Area “A”

 

 

 

 

(Default = 1)

 

2 = Assigned to Area “B”

 

User Code Access Options

 

P4E 

1-100E 

Users 1-100 Access Options 

(Default 1-4

)  

1 = Code can Arm Area

 

 

 

 

(Default = 1,3,4)

 

2 = Code can arm Stay Mode

 

 

 

 

3 = Code can Disarm Area

 

 

 

 

4 = Code can disarm Stay Mode

 

 

 

 

5 = Code is a Security Guard Code

 

 

 

  

6 = Code will Arm Latchkey Mode

 

 

 

 

7 = Call Divert Code

 

 

 

 

8 = Can View Event Memory 

User Code Privileges

 

P5E 

1-100E 

Users 1-100 Privileges 

1 = User can Change their Code

 

 

 

 

(Default User 1 = 2,3,4,5,6,7,8)

 

2 = User can Change All Codes

 

 

 

 

(Default User 2-100 = All Off)

 

3 = User can Allow Access to Installer Mode/Edit all Codes

 

 

 

 

4 = User can Change Telephone Numbers

 

 

 

 

5 = User can Change the Clock

 

 

 

  

6 = User can Change DTMF Command Codes

 

 

 

 

7 = User can Learn New Radio Devices

 

 

 

 

8 = User can Force a Download to Callback Number

 

Radio User Type

 

P7E 

21-100E  Radio User 21-100 Type 

0 = General Pendant Type

 

 

 

 

(Default = 0)

 

1 = Crow Freelink Pendant

 

 

 

 

21 = Ness Pendant 

Radio User Privileges

 

P8E 

21-100E  Radio Users 21-100 Privileges  

1 = Pendant Can Disarm at All Times

 

 

 

 

(Default = 1)

 

2 = Pendant Causes Immediate Panic

 

 

 

 

3 = Pendant Causes Delayed Panic ( 1.5 Sec)

 

 

 

 

4 = Pendant only works during Entry Delay

 

 

 

 

5 = This User is a Duress Code (Users 21-100)

 

 

 

  

6 = Spare

 

 

 

 

7 = Spare

 

 

 

8 = Spare

 

Time Zone Assigned to a User

 

P9E 

1-100E 

Time Zone to User # 1-100 

1 = User Controlled by Time Zone # 1

 

 

 

 

(Default = All Off) 

 

2 = User Controlled by Time Zone # 2 

 

 

 

 

3 = User Controlled by Time Zone # 3 

 

 

 

 

4 = User Controlled by Time Zone # 4 

 

 

 

 

5 = User Controlled by Time Zone # 5 

 

 

 

 

6 = User Controlled by Time Zone # 6 

 

 

 

 

7 = User Controlled by Time Zone # 7 

 

 

 

 

8 = User Controlled by Time Zone # 8

 

User to Keypad Assignment 

P10E 

1-100E 

User # 1-100 Keypad Assignment

 

1 = Can Operate at Keypad # 1

 

 

 

(Default = All On)

 

 

2 = Can Operate at Keypad # 2 

 

 

 

 

3 = Can Operate at Keypad # 3 

 

 

 

 

4 = Can Operate at Keypad # 4 

 

 

 

 

5 = Can Operate at Keypad # 5 

 

 

 

 

6 = Can Operate at Keypad # 6 

 

 

 

 

7 = Can Operate at Keypad # 7 

 

 

 

 

8 = Can Operate at Keypad # 8

 

Содержание Elite S V9

Страница 1: ...Proudly Designed and Manufactured in New Zealand ProgramSummary Guide ELITE S Version Arrowhead Alarm Products Ltd 8 16ZoneControlCommunicator V9...

Страница 2: ...7 8 2 User can Change All Codes Default User 2 100 All Off 3 User can Allow Access to Installer Mode Edit all Codes 4 User can Change Telephone Numbers 5 User can Change the Clock 6 User can Change D...

Страница 3: ...rn off Output 6 7 User Can Turn off Output 7 8 User Can Turn off Output 8 Radio Pendant Panic Alarm to an Output P15E 21 100E Radio 21 100 Panic Alarm to an O P 1 Radio panic to Output 1 Default 1 2 2...

Страница 4: ...firmed alarms 2 Entry to installer mode resets tamper alarms 3 Entry to installer mode resets low battery alarms 4 Entry to installer mode resets supervisory alarms 5 Cannot Arm if there is a keypad F...

Страница 5: ...ing 4 Pulse Output on Kiss off Following a Zone Alarm 5 Output Disabled when P25E3E timer is running 6 Spare 7 Spare 8 Spare Programming Output Options D P37E 1 8E Options D for Outputs 1 8 1 Siren Dr...

Страница 6: ...fault All Off 2 Area B Area A B Pendant or Access Tag Arm Chirp to Output P50E 1 2E Area A B Arm Chirp to Output Value 1 8 for Outputs 1 8 1 Area A Default All Off One chirp to the output for arm 2 Ar...

Страница 7: ...s A B 2 Area B Area A B Armed Mode Exit Delay to Output P65E 1 2E Area A B Armed Exit Delay to Output Value 1 8 for Outputs 1 8 1 Area A Default All Off 2 Area B Area A B Stay Mode Exit Delay to Outpu...

Страница 8: ...A Button can Stay Mode Arm 3 A Button can Disarm at All Times 4 A Button can Disarm Stay Mode at All Times 5 A Button can Reset Alarms 6 A Button can Arm Latchkey Mode 7 A Button can Disarm During Ex...

Страница 9: ...will turn on Output 2 3 The Keypad Duress Alarm will turn on Output 3 4 The Keypad Duress Alarm will turn on Output 4 5 The Keypad Duress Alarm will turn on Output 5 6 The Keypad Duress Alarm will tur...

Страница 10: ...KP 4 5 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 5 6 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 6 7 A Wrong Code or KP Tamper Alarm at Keypad 1 8 will Beep KP 7 8 A Wr...

Страница 11: ...ne will Not Report 24 hour Alarms via Dialler 7 Pulse Output on Kiss off Following an alarm 8 Exit Terminator Programming Zone EOL End of line Options P125E 1 8E Programming Zone EOL Options 0 Short C...

Страница 12: ...On Output 1 2 A Chime Zone Alarm will Turn On Output 2 3 A Chime Zone Alarm will Turn On Output 3 4 A Chime Zone Alarm will Turn On Output 4 5 A Chime Zone Alarm will Turn On Output 5 6 A Chime Zone A...

Страница 13: ...eep Keypad 2 3 A Radio Supervise Alarm will Beep Keypad 3 4 A Radio Supervise Alarm will Beep Keypad 4 5 A Radio Supervise Alarm will Beep Keypad 5 6 A Radio Supervise Alarm will Beep Keypad 6 7 A Rad...

Страница 14: ...E Zone Bypass Alarm 4 2 Reporting Code Two digit value from 00 FF Zone Bypass 4 2 Restore Reporting Codes P156E 1 16E Zone Bypass Restore 4 2 Code Two digit value from 00 FF Zone Alarm Contact ID Repo...

Страница 15: ...ed Alarm to output 2 3 Zone Confirmed Alarm to output 3 4 Zone Confirmed Alarm to output 4 5 Zone Confirmed Alarm to output 5 6 Zone Confirmed Alarm to output 6 7 Zone Confirmed Alarm to output 7 8 Zo...

Страница 16: ...5 Enabled Throughout the call in Armed State only 6 Enabled Throughout the call in Stay Mode State only 7 Listen in Enabled when the panel answers a call 8 Enabled at All Times Dialling Pre fix Number...

Страница 17: ...phone Number P184E 1 8E Maximum Dial Attempts per Telephone Number Value 0 99 Default 20 Dialler Reporting Options A P186E 1 8E Dialler Options A 1 Report Mains Failure Default All On 2 Report Battery...

Страница 18: ...ote Arm Disarm 4 2 Reporting Codes P195E 7E 4 2 Code for Remote Arming Full Arm or Stay Mode Arm Two digit value from 00 FF P195E 8E 4 2 Code for Remote Disarm Two digit value from 00 FF Duress Alarm...

Страница 19: ...A Medical Alarm SIA Reporting Code P197E 3E Medical Alarm SIA Reporting Code Default value 5 Medical Alarm Event Code MA Panel Diagnostic Default Options Display Panel Software Version Number P200E 1E...

Страница 20: ...ck Arm 408 000 Arm Disarm by single button Arm Disarm by user code 401 001 to 100 Arm Disarm by User 1 100 Arm Disarm by Radio key 400 021 to 100 Arm Disarm by Radio User 21 100 Arm Disarm by Key swit...

Страница 21: ...Armed by Time Zone CA OA Stay Mode Armed by User Pendant KS STAY Button CG OG Fail to Arm by Time Zone CI Program Mode Entry Exit LB LX Checksum Fail Corrupt EEPROM Data YF Time Changed JT Keypad Bus...

Страница 22: ...models only inhibit arming on a battery low 3 Option 5 at P25E11E was added Option 5 inhibits arming during a missing keypad alarm 4 Option 6 at P25E11E was added Option 6 inhibits arming during a tel...

Страница 23: ...11E were all defaulted to 1 which meant all of those events would report when set to Domestic or Voice reporting format If they were not required the value needed to be set to 0 to stop it reporting T...