Administrator’s Handbook
148
The auto-config server is specified by URL and port number. The format for the ACS URL is as follows:
http://some_url.com:port_number
or
http://123.45.678.910:port_number
On units that support SSL, the format for the ACS URL can also be:
https://some_url.com:port_number
or
https://123.45.678.910:port_number
TR-064
Forum LAN Side CPE Configuration (TR-064) is an extension of UPnP. It defines more services to locally manage
the ARRIS
®
Device. While UPnP allows open access to configure the Device's features, TR-064 requires a pass-
word to execute any command that changes the Device's configuration.
set management lanmgmt enable [ off | on ]
Turns TR-064 LAN side management services on or off. The default is
off
.
set management shell idle-timeout [ 1...120 ]
Specifies a timeout period of inactivity for telnet access to the Gateway, after which a user must re-login to the
Gateway. Default is
15
minutes for telnet.
set management shell ssh-port [ 1 - 65534 ]
Specifies the port number for secure shell (SSH) communication with the ARRIS® Gateway. Defaults to port
0
(off).
set management shell telnet-port [ 1 - 65534 ]
Specifies the port number for telnet (CLI) communication with the ARRIS® Gateway. Because port numbers in
the range 0-1024 are used by other protocols, you should use numbers in the range 1025-65534 when assign-
ing new port numbers to the ARRIS® Gateway telnet configuration interface. A setting of
0
(zero) will turn the
server off.
set management upnp enable [ off | on ]
Turns Universal Plug-and-Play (UPnP) on or off.
set management web http-port [ 1 - 65534 ]
Specifies the port number for HTTP (web) communication with the ARRIS® Gateway. Because port numbers in
the range 0-1024 are used by other protocols, you should use numbers in the range 1025-65534 when assign-
ing new port numbers to the ARRIS® Gateway web configuration interface. A setting of
0
(zero) will turn the
server off.
set management web https-port [ 1 - 65534 ]
Sets the secure web access port for secure management of the ARRIS® Gateway. Default is port
443
.
Содержание NVG595
Страница 1: ...ARRIS NVG595 Fiber Business Gateway ARRIS Embedded Software Version 9 1 2 Administrator s Handbook ...
Страница 10: ...Administrator s Handbook 10 ...
Страница 65: ...65 ...
Страница 68: ...Administrator s Handbook 68 ...
Страница 84: ...Administrator s Handbook 84 The following is an example log portion saved as a TXT file ...
Страница 90: ...Administrator s Handbook 90 ...
Страница 185: ...185 Please visit http www ARRIS com recycle for instructions on recycling ...
Страница 210: ...Administrator s Handbook 210 ...
Страница 220: ...Administrator s Handbook 218 ...
Страница 224: ...Administrator s Handbook 222 ...
Страница 226: ...Administrator s Handbook 224 ...