Power SourcePower Source
17
Power Source
AC Power
The Orbiter is equipped with an auto-sensing switch-mode power supply that adapts automatically to
100 V - 240 V ~, 50 / 60 Hz (nom.).
Make sure that no person stares at the light output aperture and the product is isolated from DMX before
you connect it to AC power.
You can hard-wire the Orbiter to a building electrical installation. Power outlets or external power switches
that supply the Orbiter with power must be located near the fixture and easily accessible so that the fixture
can easily be disconnected from power. Alternatively you can use a mains cable with inline main switch
and suitable mains plug.
The Orbiter is connected to the power source via a mains cable with a Neutrik® PowerCON® TRUE1 TOP
cable connector. ARRI supplies various mains cables with PowerCON® TRUE1 TOP connectors as ac-
cessories. The mains cable must always meet the following specification.
The mains cable is available as an accessory. We recommend the use of original ARRI mains cables.
Region
Cable Quality
Temperatur range
Standards
EU,
China
Rubber cord
H07RN-F 3G1,5
min. -20° C to +85° C
min. -4° F to +185° F
HAR, CCC
USA,
Canada
Rubber cord
SJ0(0)W 3x14 AWG
min. -20° C to +90° C,
min. -4° F to +194° F
300 V, min. 15 A
UL, CSA
Japan
Flexible cord
HVCTF 3X2.0 mm²
min. +60° C (+140° F),
min. 300 V, 80 shore
PSE, JET
Table 1: Mains cable specification
DANGER
High voltage! Risk of electric shock and fire.
For protection from electric shock, always connect the fixture electrically to ground (earth)
when connected to AC power. The AC mains power supply must be fitted with a fuse or
circuit breaker and ground-fault (earth-fault) protection.
Use only an ARRI mains cable or loop-through mains cable or cables which fulfill the specifications
from ARRI. The use of other mains cables might cause electric shock, malfunction and damage of
the product.
Do not connect or disconnect the mains cable when powered. The connectors can be damaged by
arcing.
Intense light! Risk of eye injury. Use an eye protection.
Ensure that persons do not look at the light output aperture without eye protection when
the product is connected to AC power or a battery pack. The product can light up suddenly.
The high intensity light beam of the product can cause eye irritation or injury when not re-
specting the safety distance.
WARNING!
Always connect the product direct to AC power. Do not connect it to a dimmer-system. Doing so will
damage the product.
NOTICE
Содержание Orbiter
Страница 1: ...L5 0021114 09 2020 S A F E T Y A N D I N S T A L L A T I O N M A N U A L ...
Страница 25: ......