ARRIMAX
– Service Manual
Page 13 of 20
Lamp Carriage Adjustment
Position the lamp carriable assembly on the
frame as shown.
Install the 4 screws (Torx 20) without
completely tightening them.
Reinstall the HT cables (13 mm wrench.)
Install 2 screws (Torx 20) on the side without
completely tightening them. The focus must be
set to flood.
Use the gauge Min or Max. The gauge set is
part number
L4.85204.E
Insert the gauge in the lamp socket as shown
and lock the lampholder.
Focus to flood. The screws on both sides on
the lamp carriage are now accessible.