• Press «ON».
• Press «ENTER».
• Pulse «0».
• Press «ENTER».
• Enter the user number (1 digit from 1 to 9) / «ENTER» / master
code / «ENTER».
The user code will be erased and the master code will be kept.
• Press “ON”.
• Press “ENTER”.
• Press “7”.
• Press “ENTER”.
• Enter the current master code and press “ENTER”
• Press “ON”.
• Press “ENTER”.
• Press “6”.
• Press “ENTER”.
• Enter the current master code and press “ENTER”.
• Enter a 2-digit number for the opening delay, OD (01-99
minutes), and a 1-digit number for the opening window, OW
(1-9 minutes).
• Press “ENTER”.
For example, if you enter 092, the OD will be 9 minutes (how
long you must wait before you can open the safe) and the OW
will be 2 minutes (time available to open the safe).
• Press ON
• Enter a user code or the current master code
• Press ENTER
• OD automatically starts: red light flashes every 5 seconds.
• OD ends: beep.
• OW automatically starts: green light flashes and beep every
5 seconds.
• Enter the opening code again during the OW and press
«ENTER». Once the light turns green you have approximately
5 seconds to turn the handle clockwise and open the safe.
You can interrupt this function by pressing “ENTER” during the
OD period. The whole sequence must be repeated.
• Press “ON”.
• Press “ENTER”.
• Press “6”.
• Press “8”.
• Press “ENTER”.
• Enter the current master code and press “ENTER”.
• Press “ON” ( The safe will beep twice) .
• Enter the number of the 1st user (1 number between 1 and
9) / “ENTER” / 6- to 8-digit user code/ “ENTER”.
• Enter the number of the 2nd user authorised for dual-mode
opening (1 number between 1 and 9) / “ENTER” / code of
2nd user / “ENTER”.
• After entering the code for the 1st user, you have 1 minute
to enter the code for the 2nd user.
The safe will emit short beeps and flashes of green light
during these 60 seconds at 5-second intervals.
When using the dual code system it is necessary to insert
the master code and the user code to open the box.
To enable this function both codes must be previously
programmed.
The
opening delay time function (OD)
refers to the amount of
time that passes between the code is entered and the door is
unlocked (green light).
The
opening window (OW)
is the period during which you can
open the door once the OD has passed. This is the same when
opening with both the master and the user code.
• Press «ON».
• Press «ENTER».
2.4. ERASING THE USER CODE
3.1. PROGRAMACIÓN DE CÓDIGO DUAL
4.1. PROGRAMMING THE OPENING DELAY TIME (OD)
AND THE OPENING WINDOW (OW)
4.2.OPENING WITH OD AND OW PROGRAMMED
4.3 CANCELLING THE PROGRAMMED OD/OW
3.2.OPENING THE SAFE WITH THE DUAL CODE
FUNCTION
3. DUAL CODE
4. OPENING DELAY TIME (OD) AND THE OPENING
WINDOW (OW)
3.3. DEACTIVATING THE DUAL CODE
• Press «ON».
• Press «ENTER».
• Pulse «3».
• Press «ENTER».
• Enter the user number (1 digit from 1 to 9) / «ENTER» / 6 to
8 digit user code / «ENTER».
• Enter the new user code and press “ENTER”.
• Enter the new user code again and press “ENTER”.
To check the new user code, press: “ON” > New user code >
“ENTER”.
2.3. CHANGING THE USER CODE
(WITHOUT THE MASTER CODE)