9

 - 

0MNPVESA52LUA

 

Network services 

NetMan 204 Solar

 implements a series of services based on the main network protocols. 

 
 

SSH 

Ssh is supported, but 

it’s reserved for service operations only. 

 
 

RFB protocol 

NetMan 204 Solar supports RFB protocol (version 3.8). This means that the user can connect with 
an application like 

VNC

1

, adding a virtual display to your inverter. The default password, asked when 

you try to connect, is “secret”. 

 
 

UDP 

UDP  (User  Datagram  Protocol)  is  a  low  level  network  protocol  that  guarantees  speed  in  the 
exchange  of  data  and  low  network  congestion.  It  is  the  protocol  used  by 

Sunvision  2

  and 

SirioDataControl

 software, for fast data read and configuration. 

The UDP connection uses the UDP 33000 port by default but can be configured on other port values 
according to requirements. 

 

 

Modbus/TCP 

The  inverter  status  can  be  monitored  by  means  of  the  standard  network  protocol  MODBUS/TCP. 
Modbus/TCP is simply the Modbus RTU protocol with a TCP interface that runs on Ethernet. 

 
 

FTP 

FTP  (File  Transfer  Protocol)  is  a  network  protocol  used  for  file  exchange. 

NetMan  204  Solar

  uses 

this protocol for: 
 

1.  download of files of the inverter values and events history log archive. 
2.  firmware upgrade (using 

SirioDataControl

 software) 

 
The FTP configuration is: 
 

  Host: hostname or 

NetMan 204 Solar 

IP address; 

  Port: default port is 21; this can be changed, if needed 

  User: ftpuser 

  Password: 

arosftp

 

 
 

SMTP 

SMTP  (Simple  Mail  Transfer  Protocol)  is  the  protocol  used  to  send  e-mails.  They  are  sent  to  an 
SMTP server on port 25 (port 25 is the default port, but it can be changed). 

NetMan 204 Solar

 can send a notification e-mail if one or more alarm or status conditions occur. The 

e-mails  can  be  sent  to  up  to  three  recipients  and  they  can  be  sent  for  five  different  alarm  kinds. 

NetMan 204 Solar

 can send periodic e-mails with an attachment containing the files of the  inverter 

values and events history log archives. 
This service can be used to periodically save the history log archives. 
The e-mail service must be enabled and correctly configured in order to send reports; the reports are 
sent to all the addresses configured for this service (for more details see paragraph 

Configuration

). 

                                                

1

 A program like TightVnc works great with NetMan 204 Solar: http://www.tightvnc.com/ 

Содержание NETMAN204 SOLAR

Страница 1: ......

Страница 2: ...L __________________________13 CONFIGURATION VIA VNC ________________________________________________15 StringBox_______________________________________________________________ 15 Inverter____________...

Страница 3: ...___ 34 Daily Data register map ___________________________________________________ 34 Characterization register map ______________________________________________ 35 DC box register map_______________...

Страница 4: ...nored Information Provides notes and useful suggestions for the User SAFETY This part of the manual contains SAFETY precautions that must be followed scrupulously The device has been designed for prof...

Страница 5: ...ferent material of which the packaging is made and dispose of all material in compliance with applicable standards in the country in which the product is used Disposing of the product The device conta...

Страница 6: ...erter can therefore be integrated easily into small medium and large sized networks The device also records inverter values and events in history log archives To view historical data you can use the S...

Страница 7: ...Solar is receiving or transmitting data packets Right LED SOLID GREEN NetMan 204 Solar is connected to a network operating at 100 Megabits per second Micro USB port NetMan 204 Solar doesn t currently...

Страница 8: ...nds and then release it Users It is possible to access to NetMan 204 Solar with the following users Username Default password Privileges ftpuser arosftp This is the FTP user that can access the log fi...

Страница 9: ...ork protocol used for file exchange NetMan 204 Solar uses this protocol for 1 download of files of the inverter values and events history log archive 2 firmware upgrade using SirioDataControl software...

Страница 10: ...instant power in KW 4 Active instant power in KW 5 External measure 6 Inverter module temperature in Celsius 7 Daily energy in KWh 8 Grid frequency in Hz 9 Grid phase R instant power in W 10 Grid phas...

Страница 11: ...previously Connect the device to the network by means of connector RJ 45 see Specifications for the cabling of the network cable STRING BOX Open the StringBox with the specific key Insert NetMan 204...

Страница 12: ...your PC IP address to the same network Install the free SirioDataControl software and simply change the IP address The details will follow in this section This method can be used to change the networ...

Страница 13: ...After installation of SirioDataControl connect your pc and the NetMan 204 Solar to the same network and run SirioDataControl Depending on if there are other inverters StringBox or not in the network...

Страница 14: ...Gateway DNS1 and DNS2 DNS Domain Name Server UDP port leave as 33000 if you don t know what to do VNC port default 5900 FTP PASV lower upper port leave as default values if you don t know what to do N...

Страница 15: ...user will be prompted with a window asking a password The default password is secret the password can be changed StringBox The StringBox shows only the configuration of IP address and relative parame...

Страница 16: ...ate in This last parameter allows the user to balance the power given by solar panels and the effective power the inverter can manage to deliver The Second button allows the user to change Administrat...

Страница 17: ...This value can be zeroed with the Zero button to start counting from the beginning again The user can change date time with the upper button on the right Hitting the Apply button on the upper right co...

Страница 18: ...rom an external source Hitting the first upper button the user can change the network parameters as seen here The user can choose DCHP or a static IP configuration Please note that invalid addresses w...

Страница 19: ...virtual screen function The use of the UDP FTP settings is straightforward the ftp NAT data ports has to be set in those cases where the user router has to be configured with NAT to allow PASV mode fr...

Страница 20: ...n Apply button is present to confirm the settings Before to do so it s better to try to test the email settings with the second button A text with OK or KO should appear just below this second button...

Страница 21: ...es each second so that the slave inverters can almost instantly adapt to the conditions required To activate the Power Reduction Function the user has to select Power Reduction checkbox and hit the Ap...

Страница 22: ...f messages if e mail settings are correctly configured If you want to activate a function just press the leftmost button just as in the following screen In this example a mail will be sent to the conf...

Страница 23: ...ide of the screen and will drive the user to the following screen This schematic view shows most of the significant values as seen from the inverter In the top right of this screen it s possible to pu...

Страница 24: ...ser can hit the second button from top and he she gets the following screen From here the user can view log data upper button or manage log data having the means to delete undesired yearly data from p...

Страница 25: ...plete because still not present The user can choose a different day using the Calendar button or can send the snapshot of the graph with the e mail button on the right The user can also drag the mouse...

Страница 26: ...right side of the main page leads the user to the following screen On this screen the user will find when available The total energy produced by the inverter The total hours of operation The actual o...

Страница 27: ...board firmware version The free RAM and flash memory occupancy in Kb and Touching the center of the screen brings the user to another screen This screen gives the user more info on the communications...

Страница 28: ...he user should choose the update file and hit the Open button the file will be transferred to the NetMan 204 Solar board After the update the board will reboot The user should be careful to choose the...

Страница 29: ...Read holding registers Read input registers Registers read All 6 0x06 Write single register Register write single Power reducer commands 16 0x10 Write multiple registers Registers write multiple Powe...

Страница 30: ...high 15 Test Fail Self test failed 14 Temperature Fail Overtemperature 13 Reserved Reserved 12 Bus Fail DC bus fail 11 GFCI Fail Ground dispersion current is too high 10 No Utility Grid voltage not pr...

Страница 31: ...0 Total output energy high register 0 1 KWh units 0 1KW Hr 32 E Total L 1 2 5 1 0 0 Total output energy low register 0 1KW Hr 33 h Total H 1 2 5 1 0 0 Operation hours high register Hr 34 h Total L 1...

Страница 32: ...Firmware version example 01 00 30h 31h 2Eh 30h 30h 89 96 Serial number 1 2 5 1 0 0 97 104 Model Name 1 2 5 1 0 0 105 112 Manufacturer 1 2 5 1 0 0 Command register map Register Name Vers Centr EVO EAS...

Страница 33: ...0 Ramp up of power gradient 0 100 0 100 6 147 RD 1 2 5 1 0 0 Ramp down of power gradient 0 100 0 100 6 148 BP 1 4 1 No Battery power 0 200 7 149 157 How power reducing is managed by Modbus The procedu...

Страница 34: ...unit 203 LOAD_POWER_3 1 3 3 1 0 0 Autoconsumo kit phase 3 100W unit Daily Data12 register map Register Name Vers Centr EVO EASY Description 501 DAILY 1 1 2 5 1 0 0 First value of average power of the...

Страница 35: ...Eight current of second module 0 1A units 918 DC_A1M3 1 2 5 No First current of third module 0 1A units 1 2 5 No 925 DC_A8M3 1 2 5 No Eight current of third module 0 1A units 926 DC_A1M4 1 2 5 No Firs...

Страница 36: ...I_String_8 String current input 8 0 1 A 28 29 30 31 32 33 34 35 36 V_REF Reference voltage 0 001 V 37 V_IN Input voltage 0 1 V 38 Analog1 Generic analog 39 Analog2 Generic analog 40 HwConfig Internal...

Страница 37: ...connectors is required The cable must conform to the standard IEEE 802 3u 100Base T with 2 pairs of UTP cables of category 5 or higher The cable between the adaptor and the hub must not be more than 1...

Страница 38: ...38 0MNPVESA52LUA...

Отзывы: