1. Introduction - Scope of the manual/Field of application
This manual refers to the
Sydney 3 VCA-VCB-SELF-H125- H150
line of refrigerated cabinets.
The scope of the information that follows is that of providing indications concerning:
- Use of the cabinet;
- Technical characteristics;
- Installation and assembly;
- Information for the personnel in charge of its use;
- Maintenance operations.
The manual should be considered part of the cabinet and must be kept for the entire life of the cabinet
itself.
The manufacturer holds itself exempt from all responsability in the following circumstances:
- Improper use of the cabinet;
- Incorrect installation, not carried out according to the norms indicated;
- Defects in the electrical supply;
- Serious lacks in required maintenance;
- Unauthorised changes and modifications;
- Use of non-original spare parts;
- Partial or total non-observance of instructions given;
N.B.Electrical appliances can be dangerous for your health.
The norms and laws in force must be respected during installation and use.
Anybody using this cabinet must read this manual.
2. Presentation - Foreseen use (Fig. 1)
The
Sydney 3
line of refrigerated cabinets is a complete line of display cases and semi-vertical wall-
units suitable for the storage and sale of
pork products, dairy products, prepared products and
meat
designed to be used with remote condenser unit.
They come in a range of models to meet the needs of the sales outlets of modern distribution. The
range is completed with corner cabinets, with open and closed 90° and 45° corners and the ROUND
version for open 90° and 45° corners.
The current versions are:
-
Sydney 3 VCA 90 / 100
in lengths 937-1250-1875-2500-3125-3750 (Fig. 1);
-
Sydney 3 VCB 90 / 100
in lengths 937-1250-1875-2500-3125-3750 (Fig. 1);
-
Sydney 3 SELF 90 / 100
in lengths 937-1250-1875-2500-3125-3750 (Fig. 1);
-
Sydney 3 H=125 / 150
in lengths 937-1250-1875-2500-3750 (Fig. 1).
For the Sydney 3 hot case and bain-marie versions (TCBM - TCPW), fish, bread, pastry and BT,
specific manuals are provided.
3. Standards and certifications, conformity statement
All models of refrigerated cabinets described in this manual and belonging to the line:
Sydney 3
meet the essential requirements concerning safety, health at the workplace and protection
required by the following European Directives:
Directive
Harmonised standards applied:
Machinery Directive - 2006/42/CE
EN ISO 14121; EN ISO 12100-1; EN ISO 12100-2; EN 378-2;
EN 378-3; EN 378-4; EN 60079-10-1
2004/108/CE Electromagnetic
Compatibility
EN 61000-3-2; EN 61000-3-12; EN 55014-1; EN 55014-2
2006/95/CE Low Voltage
EN 60335-1; EN 60335-2-89/A2
RoHs Directive 2011/65/CE;
(restricted use of certain hazardous
substances in electrical and electronic
equipment)
EN 50581
European Regulation
EC-1935/2004
(on materials intended for contact with
the goods)
EN 1672-2
Содержание Sydney 3 H125
Страница 4: ...Sydney 3 VCA VCB SELF H125 H150 4 05060057 01 28 08 2015 7 8 8 10 11 9 M6 M6 M5 Rif 10 Rif 11 ...
Страница 23: ...Sydney 3 05060057 01 28 08 2015 23 14 Montare il cristallo frontale 15 Regolare i cristalli frontali ...
Страница 35: ...Sydney 3 English 05060057 01 28 08 2015 35 14 Assemble the frontal crystal 15 Adjust the frontal crystals ...
Страница 61: ...Sydney 3 Français 05060057 01 28 08 2015 61 14 Monter la vitre frontale 15 Régler les vitres frontales ...
Страница 73: ...Sydney 3 Español 05060057 01 28 08 2015 73 14 Montar el cristal frontal 15 Ajustar los cristales frontales ...
Страница 86: ...Sydney 3 86 05060057 01 28 08 2015 14 ɍɫɬɚɧɨɜɢɬɶ ɮɪɨɧɬɚɥɶɧɨɟ ɫɬɟɤɥɨ 15 Ɉɬɪɟɝɭɥɢɪɨɜɚɬɶ ɩɟɪɟɞɧɢɟ ɫɬɺɤɥɚ ...
Страница 100: ...Sydney 3 Português 30 08 2007 23 14 Montar o vidro frontal 15 Ajustar os vidros frontais ...