M al ag a
E n g l i s h
05060172 00 11-07-2017
3 3
Safe handling
(how to
proceed)
•
make sure there are no foreign objects within the handling area
•
always place correctly the lifting brackets
•
always introduce the brackets completely
•
distribute the weight of the cabinet to ensure balance of the load barycentre (Fig.3)
WARNING! Heavy object. Crushing
Observe the indications regarding safe handling
Dragging. Collapse/deformations/tear-off
DO
NOT drag/push the cabinet
DO
NOT use the glass panels for attachment/support/grip
Observe the indications regarding safe handling
i
DO
NOT use transportation procedures other than those indicated
12. Storage
Remedy
•
the cabinets must be stored indoors, with a temperature ranging between-
25°C and +55°C and a humidity between 30% and 90%.
•
before storing the cabinets, check that the packing is intact and that it does
not display defect that may compromise preservation of the cabinets.
What to avoid
UV rays. Permanent deformation of plastic materials /damage of cabinet parts.
DO
NOT store the cabinets in uncovered areas exposed to atmospheric
agents and to direct sunlight.
13.
Installation, environmental conditions, first cleaning
WARNING!
Before carrying out any operation take all possible precautions to prevent injury to the
operator, use the individual Personal Protection Equipment provided (chap.3).
Installation is reserved to technicians trained and authorized by the body specified in the
contract (manufacturer/dealer/distributor)
i
-
It is the responsability of the customer to provide the installation area
-
Changes to the setup described here must be authorized by ARNEG S.p.A.
The cabinet can be delivered packed as follows:
•
with frame in wood fixed to the base and nylon casing blocked by straps (standard) (Fig.5).
•
with a cardboard casing (on request) (Fig.6).
•
with wooden crate (upon request) (Fig.7).
The installa-
tion
area should
•
comply with the local standards in force
•
comply with the environmental climatic class chap.9
•
have a floor able to support the weight of the cabinet
•
a switch with automatic protection against short circuits, ground discharges
and dispersions between the electric power line and the machine;
•
provide the space required for correct ventilation, use and maintenance.
Environmental
conditions
For the cabinet to work properly, the room temperature and relative humidity
must not exceed the limits of a climate class 3 (+25°C; R.H. 60%) according to the
standard EN-ISO 23953 - 2.
Cabinet
delivery
•
make sure the packing is intact and that it does not display readily apparent damages;
•
carefully perform the unpacking operation in order not to damage the cabinet;
•
check that cabinet components are intact
•
should you notice any damage immediately inform the manufacturer
Содержание Malaga H160 ventilated
Страница 2: ......