background image

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0378424B

Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

6W

Fan Assembly

1

0058698

Fan Motor, Evaporator

0142780

Fan Blade
embossing toward motor

B.

0411744

Standard Non-adjustable 

2

Thermostat

C.

0137880

Optional Adjustable 

3

Refrigeration Thermostat

Note:  

Changed items have been underlined.

Merchandisers

®

D

E

B

D

C

E

A

P2

Data Sheet Set

P/N 0378424B

NSF

®

Certified

December, 2003

Item

Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D.

0428648

Ballast 2 lamps

4

D.

0428649

Ballast 3 lamps

4

E.

Fluorescent Lamp

5

Replace with like fixtures

Содержание Impact P2

Страница 1: ...ing toward motor B 0411744 Standard Non adjustable 2 Thermostat C 0137880 Optional Adjustable 3 Refrigeration Thermostat Note Changed items have been underlined Merchandisers D E B D C E A P2 Data Sheet Set P N 0378424B NSF Certified December 2003 Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast 2 lamps 4 D 0428649 Ballast 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixt...

Страница 2: ...0 5 8 1032 Distance between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of case to center of knocko...

Страница 3: ...TIME P2 P2E Temp Term F 48 F 48 F Failsafe Minutes 30 30 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise close 48 F open 33 F CONVENTIONALCONTROLS Low Pressure Backup Control P2 P2E CI CO 14 4 F 17 7 F Indoor Unit Only Pressure Defrost Termination 48 F Use a Temperature Pressure Chart to determine PSIG conversions PHYSICAL DATA Merchandiser Drip Pipe in 1 1 2 Liquid Line ...

Страница 4: ... 56 0 84 88 132 Energy Efficient 120V 60Hz 0 52 0 78 36 54 Constant on Anti sweat Heaters NA Cycling Anti sweat Heaters NA Min Circuit Ampacity With Standard Fans 120V 60Hz 1 20 1 70 Export 230V 50Hz 0 76 1 04 With Energy Efficient Fans 120V 60Hz 0 72 0 98 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA...

Страница 5: ... Green BL Blue B Black W White 120V POWER 120V NEUTRAL FIELD GROUND WARNING All components must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS CASE GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shel...

Страница 6: ...0V NEUTRAL Grayed components in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White Optional Lighting 1 Row Rail 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R R BL BL 4 BL R R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R R BL BL 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER O...