Lisbona
English
40
05060030 03 30-07-2015
1. Introduction - Purpose of the manual/Application field
This instruction manual refers to the
Lisbona
refrigerated cabinets.
The information that follows provides indications relating to:
- Use of the cabinet - technical features- installation and assembly - information for the operator in charge of
use - maintenance interventions.
This manual is to be considered part of the cabinet and must be preserved for its entire duration.
The manufacturer cannot be held responsible for:
- Improper use of the cabinet - incorrect installation not carried out in compliance with the standards
indicated - electric power supply faults - lack of envisioned maintenance - unauthorised modifications and
interventions - use of non original spare parts - partial or total non observance of the instructions.
This manual must be available at all times for consultation by the operators and the staff in charge of
maintenance. In case of transfer to third parties, this manual must be provided to the new user or owner. The
supplier must also be informed of the transfer.
In case of damage or loss, request a copy from the supplier.
Note: Electric appliances may be dangerous for ones health. Regulations and existing laws in force
must be respected during installation and use.
Whoever uses this cabinet must read this manual.
2. Presentation - Expected Use (Fig. 1)
The
Lisbona
line of refrigerated cabinets is composed of vertical wall display cabinets, open-fronted,
designed for foodstuffs with a remote condensing unit, suitable for the conservation and self service sale of
Cold Meats, Dairy Products, Fruit and Vegetables and Meat
.
Their great display and loading capacity together with a reduced size makes them suitable for any type of shop.
3. Norms anStandards and certifications, conformity statement
All models of refrigerated cabinets described in this manual and belonging to the line:
Lisbona
meet the essential requirements concerning safety, health at the workplace and protection required
by the following European Directives:
The performance of these refrigerated cabinets was determined through tests conducted in compliance with
standard:
-
EN ISO 23953:2012
in environmental conditions corresponding to climatic class 3
(25 °C , 60% U.R.) see table:
Environmental climatic classes as per UNI EN ISO 23953
Directive
Harmonised standards applied:
Machinery Directive - 2006/42/CE
EN ISO 14121; EN ISO 12100-1; EN ISO 12100-2; EN 378-2;
EN 378-3; EN 378-4; EN 60079-10-1
2004/108/CE Electromagnetic
Compatibility
EN 61000-3-2; EN 61000-3-12; EN 55014-1; EN 55014-2
2006/95/CE Low Voltage
EN 60335-1; EN 60335-2-89/A2
RoHs Directive 2011/65/CE;
(restricted use of certain hazardous
substances in electrical and electronic
equipment)
EN 50581
European Regulation
EC-1935/2004
(on materials intended for contact with the
goods)
EN 1672-2
Article 3 section 3 of Directive
CEE 97/23 (PED)
does not apply to these cabinets.
Climatic Class of the
testing chamber
Dry bulb temp.
Relative Humidity
Dew point
Weight of water vapour in
dry air
°C
%
°C
g/kg
0
20
50
9,3
7,3
1
16
80
12,6
9,1
i