Operational Specifications
Technical Specifications
Specifications
• Flo-Direct
®
water heaters are built to UL standard 795
• May be manufactured to comply with various other electrical or water quality standards
• Three-phase power is required; most available voltages may be accommodated
*Consult factory for additional information.
Materials of Construction
Heater
Component
Material
Canister
304 SS (10 ga.
≤
AFD-9000; 3/16 > AFD-9000)
Canister gasket
WARCO white (food grade buna rubber)
Flame tube
304 SS
Gas piping
Malleable iron with standard yellow finish
Water piping
Welded stainless steel (304)
Spray ring
304/316 SS
Pall ring
304 SS
Spec
English Units
SI Units
Gas supply pressure
2–6 psig (optimum 4–5.5 psig)
0.14–0.41 bar (optimum 0.28–0.38 bar)
Water supply pressure
30–100 psig with ± 5 psig variation
2.07–6.84 bar with ± 0.34 bar variation
Inlet water temperature
32 °F to 1
00
°F
0 °C to
37
.7
°C
Outlet water temperature
18
0
°F
8
2
.2
°C
Water temperature differential
10 °F to 140 °F
5.6 °C to 77.8 °C
NOx emission
6
0–
7
0 ppm
Thermal efficiency
99.7%