28
Pictures for illustrating purposes only
ALL WORKS CONCERNED WITH ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY A SKILLED AND QUALIFIED PERSONNEL
Series EHU-750 steam humidifier in 3 X 415V - 50/60 Hz
EHU-750
Steam production
(Kg/h)
In
Imaxi
Pmaxi
Cylinder size
Steam
Torroidal
( A )
( A )
( KW )
diameter
transformer
wiring
752-5
5
5,3
6
4,26
Small
25
Loop
752-8
8
8,5
9,3
6,60
Small
25
Straight through
752-10
10
10,6
11,6
8,23
Small
25
Straight through
752-15
15
15,9
17,1
12,14
Small
25
Straight through
753-20
20
21,2
22,7
16,11
1 x Large
40
Straight through
753-30
30
31,8
33,9
24,06
1 x Large
40
Split
753-30HC
33
35
37,3
26,44
1 x Large
40
Split
754-40
40
42,4
45
31,93
2 x Large
40
Straight through
754-50
50
53
56,2
39,88
2 x Large
40
Split
754-60
60
63,6
67,3
47,76
2 x Large
40
Split
754-60HC
66
70
74,1
52,59
2 x Large
40
Split
755-90
90
95,4
100,8
71,53
3 x Large
40
Split
755-90HC
99
105
111
78,74
3 x Large
40
Split
Series EHU-750 steam humidifier in 3 X 480V - 50/60 Hz
EHU-750
Steam production
(Kg/h)
In
Imaxi
Pmaxi
Cylinder size
Steam
Torroidal
( A )
( A )
( KW )
diameter
transformer
wiring
752-5
5
4,6
5,2
4,25
Small
25
Loop
752-8
8
7,3
8
6,58
Small
25
Straight through
752-10
10
9,2
10,1
8,27
Small
25
Straight through
752-15
15
13,7
14,9
12,22
Small
25
Straight through
753-20
20
18,3
19,6
16,09
1 x Large
40
Straight through
753-30
30
27,5
29,3
24,06
1 x Large
40
Split
753-30HC
33
30
32
26,25
1 x Large
40
Split
754-40
40
36,6
38,9
31,95
2 x Large
40
Straight through
754-50
50
45,8
48,5
39,85
2 x Large
40
Split
754-60
60
55
57,7
47,37
2 x Large
40
Split
754-60HC
65
60
63,6
52,18
2 x Large
40
Split
755-90
90
82,4
87
71,43
3 x Large
40
Split
755-90HC
99
91
96,2
78,98
3 x Large
40
Split
SERIES EHU-750 HUMIDIFIER