Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit
armstrong
international.com for up-to-date information.
123
AVI
Armstrong Honey-V Insertion Vortex
Product Code
Process Connections
CT8
Compression, 2 inch NPT
CF8150
Compression, 2 inch 150# Flange
CF5016
Compression, DN50 PN16 Flange
CF8300
Compression, 2 inch 300# Flange
CF5040
Compression, DN50 PN 40 Flange
CF8600
Compression, 2 inch 600# Flange
CF5064
Compression, DN50 PN64 Flange
PT8
Packing Gland, 2 inch NPT
PF8150
Packing Gland, 2 inch 150# Flange
PF5016
Packing Gland, DN50 PN16 Flange
PF8300
Packing Gland, 2 inch 300# Flange
PF5040
Packing Gland, DN50 PN40 Flange
PT8R
Packing Gland, 2 inch NPT, Retractor
PF8150R
Packing Gland, 2 inch 150# Flange, Retractor
PF5016R
Packing Gland, DN50 PN16 Flange, Retractor
PF8300R
Packing Gland, 2 inch 300# Flange, Retractor
PF5040R
Packing Gland, DN50 PN40 Flange, Retractor
PF8600R
Packing Gland, 2 inch 600# Flange, Retractor
PF5064R
Packing gland, DN50 PN64 Flange, Retractor
Temperature Options
T
Standard temperature, Process temperature -330°F - 500°F (-200°C - 260°C)
H
High temperature, Process temperature up to 750°F (400°C)
Pressure Options
N
No pressure sensor
1
Maximum 30 psia (2 bara), Proof 60 psia (4 bara)
2
Maximum 100 psia (7 bara), Proof 200 psia (14 bara)
3
Maximum 300 psia (20 bara), Proof 600 psia (41 bara)
4
Maximum 500 psia (34 bara), Proof 1000 psia (64 bara)
5
Maximum 1500 psia (100 bara), Proof 2500 psia (175 bara)
Output
1
One 4-20mA analog output, scaled frequency, one pulse, HART™, LP power only
2
One 4-20mA analog output, scaled frequency, one alarm, one pulse, HART™, DC or AC power
3
One 4-20mA analog output, scaled frequency, one alarm, one pulse, Modbus, DC or AC power
4
One 4-20mA analog output, scaled frequency, one alarm, one pulse BACnet™, DC or AC power
5
Three 4-20mA analog outputs, scaled frequency, three alarms, one pulse, HART™, DC or AC power
6
Three 4-20mA analog outputs, scaled frequency, three alarms, one pulse, Modbus, DC or AC power
7
Three 4-20mA analog outputs, scaled frequency, three alarms, one pulse, BACnet™, DC or AC power
Input Power
LP
12-36VDC, 25mA, 1W max, loop powered, output option 1 only
DC
12-36VDC, 300mA, 9W max, output options 2, 3, 4, 5, 6, 7
AC
10-240VAC, 5W max, output options 2, 3, 4, 5, 6, 7
Electronics
D
NEMA 4X Enclosure
R
Remote NEMA 4X Enclosure
Multivariable Options
V1
Volumetric
V2
Velocity, Temperature
V3
Velocity, Temperature, Pressure
V4
Velocity, Temperature, External Pressure
E1
Energy
E2
Energy, Pressure
Probe Length
S
Standard Length
C
Compact Length
E
Extended Length
AVI
CF8150
S
V2
D
DC
2
T
N
AVI Ordering Information