15
If the Sensor detects a strong reflection (or similar), the spout will turn on and off intermittently with no
one present (Pulsing On / Off). In the unlikely event that this does happen, the Sensing Range must be
reduced.
Ranging can be done using one of two ways: (A) manually or by (B) using a remote sensor program-
ming unit.
If the installer wishes to position the PSU in the ceiling area for example, then cable
extensions are available:
SENSOR & SOLENOID EXTENSION LEADS: A963703NU: (Pair, 2M long).
Containing grey power lead for sensor & black/red lead for solenoid.
LINK CABLES: A962281NU (1.5M), A962282NU (3M) & A960707NU (10M).
A. Manually Changing Sensor Range
1. Turn Power to sensor OFF.
2. Wait 60 seconds, turn power ON . . .
3.
IMMEDIATELY
move hand very close to
sensor (A) (palm towards sensor)
4. Leave hand in place for 7 seconds.
5. Move hand to Position (B)
(This will set the Sensing Range)
6. Leave hand in place for 7 seconds
Move hand away from Sensor / Tap.
7. Wait 5 seconds for sensor to store data.
8. Sensor Range is now set.
9. Check tap works properly by bringing
hand towards tap.
(Total range is from 50mm to 250mm).
B. Remote sensor programming unit
is a hand held unit which can be used to change sensor range &
other functions if required. Detailed instructions for using this unit are provided with the unit.
(This unit can be purchased separately. For spares code, see section 10)
See maintenance section for a quick overview of how to use this unit to evoke the optional hygiene flush
function.
7
SENSOR RANGING
For more information on spare parts why not visit our spare website:
www.fastpart-spares.co.uk.
Or contact customer care
fast
t
r
a
p
Extension cables
Factory default ranges are set to:
147 mm (150 spout) &
227 mm (230 spout).
DURING SETTING UP
PROCEDURE AVOID HIGH
VISIBILITY CLOTHING
CABLES SHOULD NOT BE CUT (OR SHORTENED), AS THIS WILL INVALIDATE WARRANTY.
Hand Position (B)
end of spout
Hand Position (A)
30 mm to 50 mm