INSTALLATION GUIDE continued…
11
10
6
7
8
9
24
24 & 25
Connection of this product to mains
power supply should be undertaken by
a competent person and should conform
to IEE Wiring Regulations
Orientation & position of solenoids, and PSU
(
P
ower
S
upply
U
nit) case can differ from in
-
stallation to installation.
With the product securely mounted to the
panel & plumbed-in, electrical work can com-
mence.
12.
Locate the end of the red & black cable
which emerges from the spout (attached to
the rear of
the sensor). This cable length is nominal
750mm.
Connect the cable to the solenoid valve termi-
nals as shown. Observe the + and – symbols
marked on the solenoid valves, connect the
red cable to + & black to -.
Refer to the diagram on the next page for PSU
connection options.
12
red
black
Power:
6W
Approval EU:
EN 60950, EN 60335
Approval UL:
UL 1310
Input voltage:
100V - 240V~ 50 - 60Hz
Protection class:
II
DIN EN 60730-1: Type 1
Each type of PSU is
identified by this
coloured dot system:
RED
DOT
BLUE
DOT
GREEN
DOT
MAINS
LINK
BATTERY
Electrical information
& approvals:
9
5.3
Electrical connection