Using jumper block S9-S11 it is possible to select any of the three input sources to connect to
each output. Fig. 2.3.4.2 illustrates the interconnection possibilities.
FIBER IN
FIBER OUT
S1 RS-422
IN A
IN B
GND
OUT A
OUT B
21
22
11
12
13
14
15
51
52
+24Vdc
0V
S2 POWER SUPPLY
S5 emergency
switch for S3
EMRG+
EMRG-
S10
S9
S11
S1
S2
Connection of selector
blocks S9 - S11
Fiber input
S3 RS-232/
RS-422 input
S1 RS-422
input
Fig. 2.3.4.2, WGT02310 interface interconnection with jumper blocks
Using led indicator lamps D1-D9 it is possible to monitor all inputs and outputs. Jumper S12
can be installed to supply the WGT02301 module from MC300 control unit via S3.
Do not install jumper S12 if you use 24V connected to S2.
The following table shows the pinout of the communications interface connector in
WGT02310. It is compatible with similar communications in other ARLACON equipment.
To connect via the D-15 connector use a suitable cable with either RS-422 or RS-232 signals
connected from "in" to "out". Other signals are connected pin-to-pin. Signals "frame gnd" are
provided for connection of cable screens and are preconnected to supply 0V in WGT02310.
If used with MC300 version with enclosure, pins 6 and 14 can be used for connecting power
from WGT 24V supply to terminal. In this case, do not connect pins 9,10 and 13.
WGT02310 S3 D-15 communications connector
pinout
PIN
signal
PIN
signal
1
2
3
4
5
6
7
8
frame ground
RS-232 in
RS-232 out
RS-422 IN A
RS-422 OUT A
0V (supply)
signal ground
EMRG+
9
10
11
12
13
14
15
(+12V)
(-12V)
RS-422 IN B
RS-422 OUT B
+5V
+24V (supply)
EMRG-
To supply power from MC300, connect S12 on WGT02310 board. Do not connect 24V supply
to WGT02310.