MAGX2 User Guide
8
V2.14 1-2-2017
After the meter is opened, pull the signal cable through the cable gland on the bottom of the transmitter
housing (see page 5).Connect the connector at the end of the signal cable from the sensor to the transmitter
circuit board.
Electrical installation should only be done by a qualified person. Standard safety regulations
for hazardous electrical installations have to be respected.
The O-ring sealing shall be exchanged every 6 months of operation.
Connect the transmitter to network power.
The customer is assumed to supply its own network power supply cable (90-250VAC, 24VDC or 12VDC,
depending on the type of power supply ordered with the flowmeter). Before connecting to network power, the
cable needs to be properly connected to the transmitter.
First pull the cable end through one of the cable glands (ideally the first on the left looking at the transmitter
housing from the back-side) on the bottom of the transmitter.
Recommend 3x1mm round crosscut cable.
After connecting the power cable, close the housing and connect the cable to network power. This will make
the flowmeter switch on.
For electrical connection the appropriate temperature rated cables have to be used
(Ta=70degC)
Set up the transmitter for use.
You are now ready to start using your flowmeter or to customize its settings as per your requirements. For
example;
- Set-up the measurement unit of flow-rate displayed, e.g. m3/hr.
- Set up of the unit for the volume displayed. For all volume counters this same unit will be used.
2.5. Module installation
- Always check if the module does not have a bent or
broken pin, before placing it in the correct module slot of
the MAGX2 motherboard.
- Always make sure you place the module in the
correct slot of the motherboard! The name that is written
on the module itself has to match the name written next
to the slot.
Placing the module in an incorrect slot can
cause damage to the module and the motherboard,
and has to be avoided by careful module installation!
-
Check whether you are placing the module in the
correct position. It does matter how you turn the module
to fit the slot! The white line around the actual slot on the
motherboard indicates the correct position of installation.
The bevelled corner should be your point of orientation
(note the picture below).