54
•
Option 2
Hold the nozzle and unscrew the nozzle head. Then
insert a screwdriver into the nozzle and position the blade in
ROGLQJWKHVFUHZGULYHU¿UPO\XQVFUHZWKHQR]]OH
001412
Figure 18. Dismantling, option 2
• Take out the nozzle at the back of the chamber and
disconnect the nozzle from the hose. The main pump can be
removed to make this operation easier. Disconnect the hoses
DQGWKHWZR¿[LQJVFUHZVXQGHUWKHSXPSVKHOI0RYHWKH
pump forward and lift it out.
•
$IWHUUHSODFHPHQWUHSDLUUH¿WLQWKHUHYHUVHRUGHU
7.5 Replacing a temperature sensor
WARNING!
2QO\WREHFDUULHGRXWE\DXWKRUL]HGVWDII
WARNING!
The machine is connected to the electricity supply
and some components are live.
• Remove the old temperature sensor by pulling it out of the
seal.
• Push the new sensor in through the seal.
1
001418
Figure 19. Placement of the temperature sensor (1)