24
,QDFWLYLW\OLQH
WARNING!
If the machine has not been used for more than
KRXUVLWLVQHFHVVDU\WRUXQDSURJUDPZLWKDQ
empty chamber before using the machine to clean
goods.
The line is used to deactivate/activate inactivity warning U9.
• 0 = Inactive
• 1
=
Active
• Default value is 1
Changing the settings requires authorization level C.
(UURUVWDWLVWLFVOLQHV±
The lines are counters for error codes. Counter codes can show
0 to 99 errors.
Line
Error code Meaning
21
F1
Temperature sensor error
24
F4
Door logic error
27
F7
Disinfection temperature not reached
within 900 sec
28
F8
Door open/unlocked during process
29
F9
Settings error (E2 error)
30
F10
&RXOGQRW¿OOHPSW\WDQN
31
F11
Leakage/drain blocked
33
F13
Internal software error
Press and hold
and
together for three seconds to reset
counters. Authorization level C is required.