![background image](http://html1.mh-extra.com/html/arjo/miranti-ceb-8x0x/miranti-ceb-8x0x_operating-and-product-care-instructions_2972251037.webp)
37
Approval label
CE marking in accordance with the Directive
93/42/EEC (The Medical Devices Directive).
The equipment has been EMC-tested and fulfils all
requirements according to IEC 60601-1-2
Identification label
The identification label states the product and serial
number and the manufacturing country.
Battery label
Classified by Underwriters
Laboratories Inc. with respect to
electric shock, fire, mechanical hazards
and other specified hazards only in
accordance with UL 60 601-1 and
CAN/CSA - C 22.2 No 601.1-M90.
US
Environmental danger.
Recyclable
Not for disposal
Pb
Labels on battery and battery charger
On the charger you will find the following
information
:
Charger
model
NDA 1200-EU
(Europe except for Great
Britain)
NDA 2200-GB
(Great Britain)
NDA 4200-US
(USA, Canada and Japan)
NDA 6200-AU
(Australia)
Mains
supply
230V, 50-60Hz ±10%
100-120V, 50-60Hz ±10%
Maxi-
mum
rated
power
230V - 0.5 A
100-120 V - 0,8 A
Output
data
28.6 V 1.2 A- yellow
27.6V thereafter - green
NDA0100
ARJO battery intended for this charger
Class II
Insulation class
Read the operation manual before use
IP2X
Use in dry areas
Made in Norway for:
Arjo Hospital Equipment AB
Eslöv Sweden
Serial No. SE 1499 0001
Battery charger for patient hoists
tested according to 60601-1
by UL International DEMKO A/S
TYPE NDA1200-EU
Arjo Hospital Equipment AB Sweden
8418518
• 230V ~ 50 - 60Hz
• Max 0,5A
• Output 28,6V 1,2A
• IP2X
• CLASS II
Only for Arjo battery No. NDA0100
Serial No. SE 3207 0076
Product no
Serial no
NDA 1200-EU
SEE0102001
Made by Arjo in Eslov, Sweden
010115
Data / Approval label
EU and US
Identification label
on the battery charger
Battery label
Identification
label
Year
Week
Serial
number
Manufacturing
works
E=Eslöv
Manufacturing
country
SE=Sweden
SEALED LEAD BATTERY
MUST BE RECYCLED OR
DISPOSED OF PROPERLY
P b
8418254
CAUTION
AVOID SHORT CIRCUIT
DO NOT CHARGE IN A
KEEP SPARKS, FLAME AWAY
SEALED CONTAINER
C
LA
SSIFIED
Medical Equipment
3P57
Classified
UL2601-1 and
CAN/CSA-C22.2 No 601.1-M90
TYPE NDA4200-US
Arjo Hospital Equipment AB Sweden
8418518
• 100-120V ~ 50 - 60Hz
• Max 0,8A
• Output 28,6V 1,2A
• IP2X
• CLASS II
Only for Arjo battery No. NDA0100
Serial No. SE 0695 0102001
US
C
SEE0102001
Содержание MIRANTI CEB 8X0X
Страница 1: ...MIRANTI Operating and Product Care Instructions 04 CE 02 8GB May 2008 0086 ...
Страница 9: ...9 1 2 3 ...
Страница 11: ...11 A B 2 1 3 4 5 6 ...
Страница 13: ...13 1 2 3 ...
Страница 15: ...15 1 2 3 5 6 7 4 8 ...
Страница 17: ...17 A B B A 2 1 ...
Страница 19: ...19 1 2 3 4 5 6 ...
Страница 21: ...21 1 5 6 2 3 4 7 8 ...
Страница 25: ...25 1 2 3 4 ...
Страница 27: ...27 1 a 2 ...
Страница 29: ...29 1 3 4 5 6 b b 2a 2b 2c ...
Страница 33: ...33 1 2 3 4 5 7 6 8 ...
Страница 41: ...ARJO Hospital Equipment AB PO Box 61 Verkstadsvägen 5 SE 241 21 Eslöv Sweden ...