- 2 -
S
PECIFICATIONS
Input voltage ........................................................................... 9.5 to 16 VDC
Current
Typical ..................................................................................... 15 mA
Maximum ................................................................................. 25 mA
Electrical configuration ....................................................................... Form C
Relay rating ....................................................................... 16 V, 50 mA max.
Tamper switch rating ....................................................... 12 V, 50 mA max.
Detection range ............................................................ 0.9 m - 7.6 m x 360°
Alarm response ................................................................................... 4 sec.
Minimum glass size ............................................................. 30.5 cm x 61 cm
Recommended glass thickness:
Plate ........................................................................ 2.5 mm - 6.5 mm
Tempered .................................................................. 3 mm 6.5 mm
Wired ...................................................................................... 6.5 mm
Laminated .............................................................................. 6.5 mm
Operating temperature ....................................................................0° - 50°C
Relative humidity .................................................. 10 - 90% non-condensing
Round housing dimensions: ............................................. 2 x 10 cm (D x
Æ
)
Rectangle housing dimensions: ....................... 11.5 x 7 x 2 cm (H x W x D)
Color
................................................................................................. White
Field wiring size ......................................................................... 18-24 AWG
S
ETTING
THE
R
ANGE
The detector has a spring clip (J3) to set room size. See Figure 4. Use the
following table to determine what setting to use for an application.
Setting
Description
Open
Sets the range for 1.5 m to 7.6 m. Use for rooms
30 m² and larger. Default
Closed
Sets the range 1 m to 3 m. Use for rooms smaller
than 30 m².
T
ESTING
THE
D
ETECTOR
Use a Sentrol 5709C hand-held tester to verify detector range and operation.
To test the detector:
1. Set the tester to the appropriate glass-type setting. Use the
tempered
setting if you are unsure about the glass type.
2. Put the detector in test mode as follows:
- Hold the tester close to the detector. See Figure 5.
- Activate the tester.
The LED on the detector lights for 4 seconds and then starts flashing to
indicate the detector is in test mode. The relay opens for 4 seconds, then
returns to standby.
3. Hold the tester near the surface of the glass to be protected and aim the
speaker at the detector. Be sure the tester is at the point on the glass
farthest from the detector. If closed curtains are present, hold the tester
behind them. See Figure 6.
4. Press the test button on the tester. The LED on the detector should stay
on for 4 seconds to indicate the glass is within detection range of the
detector.
If the LED does not stay on for 4 second
s, move the detector
and retest.
U
NDERSTANDING
THE
LED
The red LED located on the front of the detector indicates the status of the
unit as follows:
Status
LED indication
Power on
Flashes when power is applied.
Clap test/Alarm
memory
In response to the clap test:
Flashes twice to indicate the detector has power
and is functioning properly.
Or
On for 4 seconds to indicate the detector has
alarmed.
Alarm
On for 4 seconds with relay when breaking glass
is detected.
Test mode
On for 4 seconds with relay, then flashes for 60
seconds. Each test trigger resets the test mode
clock and the LED restarts flashing for 60
seconds.
U
SING
THE
H
AND
-C
LAP
T
EST
AND
A
LARM
M
EMORY
Check the alarm memory and detector operation with the hand-clap test as
follows:
1. Standing under the detector, clap your hands together.
2. Observe the LED on the detector.
If the detector has power and is functioning properly
, the LED quickly
flashes twice.
If the detector has alarmed
, the LED will light for 4 seconds. Cycle the
power to clear the alarm memory.
The hand-clap test is intended as a functional test and is not an accurate
indication of detector range.
J3 Spring clip
Figure 4 - Detector Knockout Locations
Figure 5 Using the Tester
Figure 6 - Testing the Range
• Single
• Contin
uous
Plate •
Tempered •
Laminated •
Batter
y LED
Batter
y is OK if LED
sta
ys on during test
5709C
Shatter Series
Tester
Use f
or testing:
ShatterPr
o
Shatterbo
x
Shatterbo
x II
ShatterSwitc
h
SENTR
OL
2.5 cm
Knockouts
Knockouts
Slot
J3
Содержание ShatterPro 3