7. Connect the system wires to the appropriate screw terminals on the base
and tighten the screws.
8. Replace the cover as follows:
- Round housing:
Line up the tabs on the base with the correspond-
ing tabs on the cover, press together and turn clockwise until the
cover snaps firmly into place. See Figure 3.
- Rectangle housing:
Press the cover back down over the detector
until the cover snaps firmly into place.
9. Apply power. The red LED should flash once.
10. Test the detector. See
Testing the Detector.
F
NL
D
I
S
DK
D
ESCRIPTION
The ShatterPro 3 is an acoustic glassbreak detector designed to detect
breaking glass from framed windows in the perimeter of a building. The
detector is mounted in the building interior and uses a power supply from a
12 VDC control panel. The detector is available in either a low-profile round
housing or a rectangular housing that connects easily to a single-gang box.
S
ELECTING
A
L
OCATION
FOR
THE
D
ETECTOR
Mount the detector on ceilings or on walls opposite or adjacent the window
to be protected. See Figure 1. Use the following guidelines to determine the
best location to install the detector.
w
Mount at least 1m from the glass windows being protected.
w
Windows must be at least 30 x 60 cm square.
w
Avoid locations where lined, insulating or sound deadening curtains are
used.
w
Mount 30cm away from wall corners.
w
Avoid locations where interior closed wooden shutters are used.
w
Locate in a suitable environment as follows:
-
Temperature between 0° and 50°C
-
Humidity between 10 and 90% non-condensing
w
Mount the detector on a stable surface up to 7.6 m from the farthest point
on the glass surface. See Figure 1.
w
Avoid locations that expose the detector to possible false alarm sources
such as: Glass airlocks and vestibule areas, kitchens, residential car
garages, small utility rooms, stairwells, bathrooms, small acoustically live
rooms, air vents.
S
ELECTING
THE
B
EST
L
OCATION
FOR
M
ULTIPLE
W
INDOW
C
OVERAGE
The detector has a 360° coverage pattern that can cover several windows
in a single room as follows (See Figure 2):
w
Draw an imaginary line from the center of each window to be covered
in towards the center of the room.
w
Mount the detector as close to where the lines intersect as possible.
w
Do not mount the detector at more than a 60° angle from the center of any
window to be protected.
I
NSTALLING
THE
D
ETECTOR
All wiring must conform to national approvals.
Important !
If you are unsure about a location, connect a 9 V battery to the
detector and test it before permanently mounting. See
Testing the Detecto
r.
To install the detector:
1. Run the security system wiring to the detector location.
2. Remove the front cover as follows:
- Round housing:
Press the release tab on the lip of the base, twist
the cover counterclockwise, and lift off.
- Rectangle housing:
Gently pry up the slot on the bottom of the
cover to unlock the cover. Lift up the cover until it latches in the open
position.
3. Set the range with J3 on the circuit board. See
Setting the Range.
4. Remove the appropriate wiring and mounting knockout holes from the
base. See Figure 4.
5. Pull the wires through the knockout holes and use two screws to attach
the base to the surface. Use wall anchors if necessary.
6. Strip 1 cm of insulation from each wire.
GB
Ceiling
mount
Detector
60° max.
60° max.
7.6 m
max.
7.6 m
max.
Ceiling
mount
Wall
mount