Ariston PH 960 T GH AUS Скачать руководство пользователя страница 7

GB

7

Ventilation
To ensure adequate ventilation, the back panel of the cabinet must be 
removed. It is advisable to install the oven so that it rests on two strips of 

wood, or on a completely flat surface with an opening of at least 45 x 560 

mm (see diagrams).

 

560 mm

.

45 mm.

Where a hob is installed above an oven without a forced ventilation cooling 
system, adequate ventilation must be provided inside the cabinet by means 

of air holes through which air can pass (see figure).

 

Electrical connection

Hobs equipped with a three-pole power supply cable are designed to operate 
with alternating current at the voltage and frequency indicated on the data 
plate (this is located on the lower part of the appliance). The earth wire in the 
cable has a green and yellow cover. If the appliance is to be installed above 
a built-in electric oven, the electrical connection of the hob and the oven must 
be carried out separately, both for electrical safety purposes and to make 
extracting the oven easier.

WIRING DIAGRAM

PAn

PA1

IGNITION

 SWITCH

ELECTRONIC

IGNITION

L

N

.......

Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data 
plate. 
The appliance must be directly connected to the mains using an omnipolar 
circuit-breaker with a minimum contact opening of 3 mm installed between the 
appliance and the mains.  The circuit-breaker must be suitable for the charge 
indicated and must comply with current electrical regulations (the earthing 
wire must not be interrupted by the circuit-breaker). The supply cable must 
not come into contact with surfaces with temperatures higher than 50°C.

!

 The installer must ensure that the correct electrical connection has been 

made and that it is compliant with safety regulations.

Before connecting to the power supply, make sure that:
•  the appliance is earthed and the plug is compliant with the law.
•  the socket can withstand the maximum power of the appliance, which is 

indicated on the data plate.

•  the voltage is in the range between the values indicated on the data plate.
•  the socket is compatible with the plug of the appliance. If the socket is 

incompatible with the plug, ask an authorised technician to replace it. Do 
not use extension cords or multiple sockets.

!

 Once the appliance has been installed, the power supply cable and the 

electrical socket must be easily accessible.

!

 The cable must not be bent or compressed.

!

 The cable must be checked regularly and replaced by authorised technicians 

only (see Assistance).

!

 The manufacturer declines any liability should these safety measures not 

be observed.

Gas connection

Installation must be in accordance with this instruction manual AS 5601.1 

‘gas installations’ for installation and pipe sizing, local gas fitting regulations, 

municipal building codes, local electrical regulations and any other statutory 
regulation by an authorised person. 
The appliance should be connected to the main gas supply or to a gas 
cylinder in compliance with current national regulations. Before carrying out 
the connection, make sure the cooker is compatible with the gas supply you 
wish to use. If this is not the case, follow the instructions indicated in the 
paragraph “Adapting to different types of gas.”
When using natural gas, install the supplied pressure regulator which complies 
with current national regulations.

!

 Check that the pressure of the gas supply is consistent with the values indicated 

in Table 1 (“Burner and nozzle specifications”). This will ensure the safe operation 

and longevity of your appliance while maintaining efficient energy consumption.

Connection with a rigid pipe (copper or steel)

!

 Connection to the gas system must be carried out in such a way as not to 

place any strain of any kind on the appliance.

There is an adjustable L-shaped pipe fitting on the appliance supply ramp 

and this is fitted with a seal in order to prevent leaks. The seal must always 

be replaced after rotating the pipe fitting (seal provided with appliance). The 

gas supply pipe fitting is a threaded 1/2 gas cylindrical male attachment. 

Flexible hose assembly (if used) must comply with AS/NZS 1869 Class B or 
D, be of appropriate internal diameter, be kept as short as possible (not to 
exceed 1.2 metres), must not be kinked or in contact with any hot surface. 
The supply connection point shall be accessible with the appliance installed.

Checking the tightness of the connection

!

 When the installation process is complete, check the pipe fittings for leaks 

using a soapy solution. Never use a flame.

Adapting to different types of gas
To adapt the hob to a different type of gas other than default type (indicated 
on the rating plate at the base of the hob or on the packaging), the burner 
nozzles should be replaced as follows:
1.  Remove the hob grids and slide the burners off their seats.
2.  Unscrew the nozzles using a 7 mm socket spanner, and replace them 

with nozzles for the new type of gas (see table 1 “Burner and nozzle 
characteristics”).

3.  Reassemble the parts following the above procedure in the reverse order.

Содержание PH 960 T GH AUS

Страница 1: ...ps 9 Maintenance and care 10 Troubleshooting 10 Sommaire Mode d emploi 1 Avertissements 2 Assistance 4 Description de l appareil 5 Installation 11 Mise en marche et utilisation 14 Précautions et conseils 14 Nettoyage et entretien 15 Anomalies et remèdes 15 Sumario Manual de instrucciones 1 Advertencias 3 Asistencia 4 Descripción del aparato 5 Instalación 16 Puesta en funcionamiento y uso 19 Precau...

Страница 2: ...evicinityofthisappliance while it is in operation Do not modify this appliance Not suitable for operation with aftermarket lids or covers fitted Where this appliance is installed in marine craft or in caravans it shall not be used as a space heater Avertissements ATTENTION Cet appareil ainsi que ses parties accessibles deviennent très chauds pendant leur fonctionnement Ilfautfaireattentionànepasto...

Страница 3: ...struidos sobre el uso del aparato de modo seguro y comprenden los peligros relacionados con el mismo Los niños no deben jugar con el aparato Las operaciones de limpieza y demantenimientonodebenserrealizadasporniños sin vigilancia ATENCIÓN Dejarunquemadorcongrasasoaceites sin vigilancia puede ser peligroso y provocar un incendio NUNCAintenteapagarunallama incendio conagua sedebeapagarelaparatoycubr...

Страница 4: ...esplazamiento a su domicilio de los técnicos Y NO PAGUE AVERIAS NUNCA MAS Servicio de asistencia técnica SAT Llame al 902 133 133 y nuestros técnicos intervendrán con rapidez y eficacia devolviendo el electrodoméstico a sus condiciones óptimas de funcionamiento En el SAT encontrará recambios accesorios y productos específicos para la limpieza y mantenimiento de su electrodoméstico a precios compet...

Страница 5: ...a puissance BRÛLEURSGAZilsontplusieursdimensionsetpuissances Choisissez celui qui correspond le mieux au diamètre de votre casserole La bougie d allumage des BRÛLEURS GAZ permet l allumage automatique du brûleur sélectionné DISPOSITIFDESÉCURITÉencasd extinctionaccidentelledelaflamme coupez immédiatement l arrivée du gaz Descripción del aparato Vista en conjunto 1 Parrillas de apoyo para RECIPIENTE...

Страница 6: ...ust not be installed or stored in rooms or storage areas that are below ground level cellars etc It is advisable to keep only the cylinder being used in the room positioned so that it is not subject to heat produced by external sources ovens fireplaces stoves etc which could raise the temperature of the cylinder above 50 C A Examples of ventilation holes for comburant air Enlarging the ventilation...

Страница 7: ... Thecablemustbecheckedregularlyandreplacedbyauthorisedtechnicians only seeAssistance The manufacturer declines any liability should these safety measures not be observed Gas connection Installation must be in accordance with this instruction manual AS 5601 1 gas installations for installation and pipe sizing local gas fitting regulations municipal building codes local electrical regulations and an...

Страница 8: ...e recommended pressure a suitable pressure regulator must be fitted to the inlet pipe in order to comply with current national regulations Electrical connections DATA PLATE EU Regulation no 66 2014 implementing Directive 2009 125 EC standard EN 30 2 1 ECODESIGN see data plate This appliance conforms to the following European Economic Community directives 2006 95 EC dated 12 12 06 Low Voltage and s...

Страница 9: ... g forheatingtheroom constitutesimproper use and is dangerous The manufacturer may not be held liable for any damage resulting from improper incorrect and unreasonable use of the appliance The openings used for ventilation and dispersion of heat must never be covered Alwaysmakesuretheknobsareinthe positionwhentheappliance is not in use Whenunpluggingtheappliancealwayspulltheplugfromthemainssocket ...

Страница 10: ... flame lifting off the burner or is not perfroming as per theoriginal installation or for service please contact Arisit Pty Ltd 1300 762 219 0 Gas tap maintenance Over time the taps may become jammed or difficult to turn If this happens the tap must be replaced Thisproceduremustbeperformedbyaqualifiedtechnicianauthorised by the manufacturer Troubleshooting It may happen that the appliance does not...

Страница 11: ...e G P L doivent prévoir des ouvertures vers l extérieur afin de permettre l évacuationdugazparlebasencasdefuitesaccidentelles Lesbouteilles de GPL qu elles soient vides ou partiellement pleines ne devront donc pas être installées ou entreposées dans des locaux qui se trouvent au dessousduniveaudusol cavesetc Ilestopportunden entreposerdans le local que la bouteille que vous êtes en train d utilise...

Страница 12: ...être contrôlé périodiquement et ne peut être remplacé que par un technicien agréé voirAssistance Nous déclinons toute responsabilité en cas de non respect des normes énumérées ci dessus Raccordement gaz Raccorderl appareilàlabouteilleouàlacanalisationdugazconformément aux normes en vigueur uniquement après avoir vérifié que l appareil est bien réglé pour le type de gaz d alimentation utilisé Dans ...

Страница 13: ...eur de pression approprié conformément aux textes réglementaires applicables dans le pays Raccordements électriques PLAQUETTE SIGNALETIQUE Cet appareil est conforme aux Directives Communautaires suivantes 2006 95 CE du 12 12 06 Basse Tension et modifications successives 2004 108 CE du 15 12 04 Compatibilité Electromagnétique et modifications successives 93 68 CEE du 22 07 93 et modifications succe...

Страница 14: ...s ou les pieds mouillés ou humides Cet appareil qui sert à cuire des aliments ne doit être utilisé que par des adultes conformément aux instructions du mode d emploi Toute autre utilisation comme par exemple le chauffage d une pièce est impropre et donc dangereux Le fabricant décline toute responsabilité en cas de dommages provoqués par un usage impropre ou erroné Evitezquelecordond alimentationd ...

Страница 15: ...d un chiffon humide pour éliminer toute trace de poussière ou de résidus d aliments cuitsauparavant Nettoyezrégulièrementlasurfacedelatableenutilisant une solution d eau tiède et de détergent non abrasif Entretien robinets gaz Il peut arriver qu au bout d un certain temps un robinet se bloque ou tourne difficilement Il faut alors le remplacer Cette opération doit être effectuée par un technicien a...

Страница 16: ...ación desde abajo de eventuales escapes de gas Además las botellas de GPL vacías o parcialmente llenas no deben ser instaladas o depositadas en ambientes o espacios a un nivel más bajo del suelo sótanos etc Esconvenienteconservarenelambientesólolabotellaque se está utilizando colocada de modo que no quede expuesta a la acción directadefuentesdecalor hornos chimeneas estufas etc capacesde llevarla ...

Страница 17: ... o el enchufe no utilice prolongaciones ni conexiones múltiples Unavezinstaladoelaparato elcableeléctricoylatomadecorrientedeben ser fácilmente accesibles El cable no debe sufrir pliegues ni compresiones El cable debe ser revisado periódicamente y sustituido sólo por técnicos autorizados verAsistencia La empresa declina toda responsabilidad cuando estas normas no sean respetadas Conexión de gas La...

Страница 18: ...ntros deAsistencia Técnica Cuandolapresióndelgasutilizadoseadistintadelaprevista ovariable es necesarioinstalar enlatuberíadeentrada unreguladordepresiónconforme con las Normas Nacionales en vigencia ver placa de características Conexiones eléctricas PLACA DE CARACTERÍSTICAS Este aparato es conforme con las siguientes Normas Comunitarias 2006 95 CE del 12 12 06 Baja Tensión y posteriores modificac...

Страница 19: ...sólo por personas adultas y siguiendo las instrucciones contenidas en este manual Cualquier otro uso como por ejemplo calefacción de ambientes se debe considerar impropio y por lo tanto peligroso El fabricante no puede ser considerado responsable por los daños derivados de usos impropios erróneos e irracionales No obstruya las aberturas de ventilación y de eliminación del calor Controle siempre qu...

Страница 20: ...e dicha llave Estaoperaciónladebeefectuaruntécnicoautorizadoporelfabricante Anomalías y soluciones Puede suceder que la encimera no funcione o no funcione bien Antes de llamar al servicio de asistencia técnica veamos qué se puede hacer Antes quenadaverifiquequenohayaninterrupcionesenlasredesdealimentación de gas y eléctrica y en particular que las llaves de gas aguas arriba del aparato estén abier...

Отзывы: