Ariston PH 960 T GH AUS Скачать руководство пользователя страница 6

6

GB

Installation

!

 Before operating your new appliance please read this instruction booklet 

carefully. It contains important information for safe use, installation and care 
of the appliance.

!

 Please keep these operating instructions for future reference. Pass them on 

to possible new owners of the appliance.

Positioning

!

 Keep packaging material out of the reach of children. It can become a choking 

or suffocation hazard (see Precautions and tips).

!

 The appliance must be installed by a authorised person according to the 

instructions provided. Incorrect installation may cause harm to people and 
animals or may damage property.

!

 This unit may be installed and used only in permanently ventilated rooms in 

accordance with AS 5601 (gas installations) current editions.
The following requirements must be observed:
•  The room must be equipped with an air extraction system that expels 

any combustion fumes. This may consist of a hood or an electric fan that 
automatically starts each time the appliance is switched on.

In a chimney stack or branched flue. 
(exclusively for cooking appliances)

Directly to 
the Outside

•  The room must also allow proper air circulation, as air is needed for 

combustion to occur normally. The flow of air must not be less than 2 m

3

/h 

per kW of installed power.

The air circulation system may take air directly 
from the outside by means of a pipe with an 
inner cross section of  at least 100 cm

2

; the 

opening must not be vulnerable to any type 
of blockages.

The system can also provide the air needed 
for combustion indirectly, i.e. from adjacent 
rooms fitted with air circulation tubes as 
described above. However, these rooms must 
not be communal rooms, bedrooms or rooms 

that may present a fire hazard.

•  Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore, 

rooms containing LPG cylinders must also be equipped with vents to allow 
gas to escape in the event of a leak. As a result LPG cylinders, whether 
partially or completely full, must not be installed or stored in rooms or 
storage areas that are below ground level (cellars, etc.). It is advisable to 
keep only the cylinder being used in the room, positioned so that it is not 

subject to heat produced by external sources (ovens, fireplaces, stoves, 

etc. ) which could raise the temperature of the cylinder above 50°C.

A

Examples of 
ventilation holes 
for comburant air.

Enlarging the ventilation slot
between window and floor.

Adjacent
Room

Room to be
Vented

Fitting the appliance
The following precautions must be taken when installing the hob:
•  Kitchen cabinets adjacent to the appliance and taller than the top of the 

hob must be at least 200 mm from the edge of the hob.

•  Hoods must be installed according to their relative installation instruction 

manuals and at a minimum distance of 600 mm from the hob.

•  Place the wall cabinets adjacent to the hood at a minimum height of 420 

mm from the hob (see figure). 

If the hob is installed beneath a wall cabinet, 
the latter must be situated at a minimum of 700 
mm above the hob.

Before the installation remove the grids and burners from the hob and turn it 
upside down, making sure you don’t damage the thermocouples and spark 
plugs.

Apply the seals that come with the appliance 
along the outer edges of the hob to prevent 
any passage of air, humidity and water (see 
Figure).
For proper application make sure the surfaces 
to be sealed are clean, dry and free of any 

grease/oil.

•  The installation cavity should have the dimensions indicated in the figure.

 

Fastening hooks are provided, allowing you to fasten the hob to tops that 

are between 20 and 40 mm thick. To ensure the hob is securely fastened 
to the top, we recommend you use all the hooks provided.

475 mm.

835 mm.

min. 55 mm.

Hook fastening diagram

 

Hooking position for top H=20mm 

Hooking position for top H=30mm

 

Front

 

Hooking position for top H=40mm 

Back

!

 Use the hooks contained in the “accessory pack”.

•  Where the hob is not installed over a built-in oven, a wooden panel must 

be installed as insulation. This must be placed at a minimum distance of 
20 mm from the lower part of the hob.

600mm min.

420mm min.

650mm min.

Содержание PH 960 T GH AUS

Страница 1: ...ps 9 Maintenance and care 10 Troubleshooting 10 Sommaire Mode d emploi 1 Avertissements 2 Assistance 4 Description de l appareil 5 Installation 11 Mise en marche et utilisation 14 Précautions et conseils 14 Nettoyage et entretien 15 Anomalies et remèdes 15 Sumario Manual de instrucciones 1 Advertencias 3 Asistencia 4 Descripción del aparato 5 Instalación 16 Puesta en funcionamiento y uso 19 Precau...

Страница 2: ...evicinityofthisappliance while it is in operation Do not modify this appliance Not suitable for operation with aftermarket lids or covers fitted Where this appliance is installed in marine craft or in caravans it shall not be used as a space heater Avertissements ATTENTION Cet appareil ainsi que ses parties accessibles deviennent très chauds pendant leur fonctionnement Ilfautfaireattentionànepasto...

Страница 3: ...struidos sobre el uso del aparato de modo seguro y comprenden los peligros relacionados con el mismo Los niños no deben jugar con el aparato Las operaciones de limpieza y demantenimientonodebenserrealizadasporniños sin vigilancia ATENCIÓN Dejarunquemadorcongrasasoaceites sin vigilancia puede ser peligroso y provocar un incendio NUNCAintenteapagarunallama incendio conagua sedebeapagarelaparatoycubr...

Страница 4: ...esplazamiento a su domicilio de los técnicos Y NO PAGUE AVERIAS NUNCA MAS Servicio de asistencia técnica SAT Llame al 902 133 133 y nuestros técnicos intervendrán con rapidez y eficacia devolviendo el electrodoméstico a sus condiciones óptimas de funcionamiento En el SAT encontrará recambios accesorios y productos específicos para la limpieza y mantenimiento de su electrodoméstico a precios compet...

Страница 5: ...a puissance BRÛLEURSGAZilsontplusieursdimensionsetpuissances Choisissez celui qui correspond le mieux au diamètre de votre casserole La bougie d allumage des BRÛLEURS GAZ permet l allumage automatique du brûleur sélectionné DISPOSITIFDESÉCURITÉencasd extinctionaccidentelledelaflamme coupez immédiatement l arrivée du gaz Descripción del aparato Vista en conjunto 1 Parrillas de apoyo para RECIPIENTE...

Страница 6: ...ust not be installed or stored in rooms or storage areas that are below ground level cellars etc It is advisable to keep only the cylinder being used in the room positioned so that it is not subject to heat produced by external sources ovens fireplaces stoves etc which could raise the temperature of the cylinder above 50 C A Examples of ventilation holes for comburant air Enlarging the ventilation...

Страница 7: ... Thecablemustbecheckedregularlyandreplacedbyauthorisedtechnicians only seeAssistance The manufacturer declines any liability should these safety measures not be observed Gas connection Installation must be in accordance with this instruction manual AS 5601 1 gas installations for installation and pipe sizing local gas fitting regulations municipal building codes local electrical regulations and an...

Страница 8: ...e recommended pressure a suitable pressure regulator must be fitted to the inlet pipe in order to comply with current national regulations Electrical connections DATA PLATE EU Regulation no 66 2014 implementing Directive 2009 125 EC standard EN 30 2 1 ECODESIGN see data plate This appliance conforms to the following European Economic Community directives 2006 95 EC dated 12 12 06 Low Voltage and s...

Страница 9: ... g forheatingtheroom constitutesimproper use and is dangerous The manufacturer may not be held liable for any damage resulting from improper incorrect and unreasonable use of the appliance The openings used for ventilation and dispersion of heat must never be covered Alwaysmakesuretheknobsareinthe positionwhentheappliance is not in use Whenunpluggingtheappliancealwayspulltheplugfromthemainssocket ...

Страница 10: ... flame lifting off the burner or is not perfroming as per theoriginal installation or for service please contact Arisit Pty Ltd 1300 762 219 0 Gas tap maintenance Over time the taps may become jammed or difficult to turn If this happens the tap must be replaced Thisproceduremustbeperformedbyaqualifiedtechnicianauthorised by the manufacturer Troubleshooting It may happen that the appliance does not...

Страница 11: ...e G P L doivent prévoir des ouvertures vers l extérieur afin de permettre l évacuationdugazparlebasencasdefuitesaccidentelles Lesbouteilles de GPL qu elles soient vides ou partiellement pleines ne devront donc pas être installées ou entreposées dans des locaux qui se trouvent au dessousduniveaudusol cavesetc Ilestopportunden entreposerdans le local que la bouteille que vous êtes en train d utilise...

Страница 12: ...être contrôlé périodiquement et ne peut être remplacé que par un technicien agréé voirAssistance Nous déclinons toute responsabilité en cas de non respect des normes énumérées ci dessus Raccordement gaz Raccorderl appareilàlabouteilleouàlacanalisationdugazconformément aux normes en vigueur uniquement après avoir vérifié que l appareil est bien réglé pour le type de gaz d alimentation utilisé Dans ...

Страница 13: ...eur de pression approprié conformément aux textes réglementaires applicables dans le pays Raccordements électriques PLAQUETTE SIGNALETIQUE Cet appareil est conforme aux Directives Communautaires suivantes 2006 95 CE du 12 12 06 Basse Tension et modifications successives 2004 108 CE du 15 12 04 Compatibilité Electromagnétique et modifications successives 93 68 CEE du 22 07 93 et modifications succe...

Страница 14: ...s ou les pieds mouillés ou humides Cet appareil qui sert à cuire des aliments ne doit être utilisé que par des adultes conformément aux instructions du mode d emploi Toute autre utilisation comme par exemple le chauffage d une pièce est impropre et donc dangereux Le fabricant décline toute responsabilité en cas de dommages provoqués par un usage impropre ou erroné Evitezquelecordond alimentationd ...

Страница 15: ...d un chiffon humide pour éliminer toute trace de poussière ou de résidus d aliments cuitsauparavant Nettoyezrégulièrementlasurfacedelatableenutilisant une solution d eau tiède et de détergent non abrasif Entretien robinets gaz Il peut arriver qu au bout d un certain temps un robinet se bloque ou tourne difficilement Il faut alors le remplacer Cette opération doit être effectuée par un technicien a...

Страница 16: ...ación desde abajo de eventuales escapes de gas Además las botellas de GPL vacías o parcialmente llenas no deben ser instaladas o depositadas en ambientes o espacios a un nivel más bajo del suelo sótanos etc Esconvenienteconservarenelambientesólolabotellaque se está utilizando colocada de modo que no quede expuesta a la acción directadefuentesdecalor hornos chimeneas estufas etc capacesde llevarla ...

Страница 17: ... o el enchufe no utilice prolongaciones ni conexiones múltiples Unavezinstaladoelaparato elcableeléctricoylatomadecorrientedeben ser fácilmente accesibles El cable no debe sufrir pliegues ni compresiones El cable debe ser revisado periódicamente y sustituido sólo por técnicos autorizados verAsistencia La empresa declina toda responsabilidad cuando estas normas no sean respetadas Conexión de gas La...

Страница 18: ...ntros deAsistencia Técnica Cuandolapresióndelgasutilizadoseadistintadelaprevista ovariable es necesarioinstalar enlatuberíadeentrada unreguladordepresiónconforme con las Normas Nacionales en vigencia ver placa de características Conexiones eléctricas PLACA DE CARACTERÍSTICAS Este aparato es conforme con las siguientes Normas Comunitarias 2006 95 CE del 12 12 06 Baja Tensión y posteriores modificac...

Страница 19: ...sólo por personas adultas y siguiendo las instrucciones contenidas en este manual Cualquier otro uso como por ejemplo calefacción de ambientes se debe considerar impropio y por lo tanto peligroso El fabricante no puede ser considerado responsable por los daños derivados de usos impropios erróneos e irracionales No obstruya las aberturas de ventilación y de eliminación del calor Controle siempre qu...

Страница 20: ...e dicha llave Estaoperaciónladebeefectuaruntécnicoautorizadoporelfabricante Anomalías y soluciones Puede suceder que la encimera no funcione o no funcione bien Antes de llamar al servicio de asistencia técnica veamos qué se puede hacer Antes quenadaverifiquequenohayaninterrupcionesenlasredesdealimentación de gas y eléctrica y en particular que las llaves de gas aguas arriba del aparato estén abier...

Отзывы: